O P E R A T I O N
Options Window
350-9047 v3.0.1
DGy Model 201x User’s Guide
50
. . . . .
or manually setting parameters prevents this from happening. 
For more details on preset and user-defined timings please see 
the 
~
Use the pull-down Input 
Timing List
 to select a pre-
defined or user-defined set of input timing parameters. 
Once selected, the parameters can be loaded or saved. 
If the timing is user-defined, it can also be deleted.
~
Click
 Load
 to load the selected set of timing parameters 
into the system’s active input registers. If desired, the 
parameters can be edited using the fields in the 
Video 
Input Timing
 section.
~
Click 
Save
 to save a modified set of timing parameters. 
Registers 100 - 160 are reserved for user-defined 
parameters. A prompt will ask to select and name a 
register.
~
Click 
Delete
 to delete a selected user-defined timing 
register. Preset registers can not be deleted.
The timing parameters displayed in the 
Video Input Timing
 
section of the page relate to the settings currently in use. When 
a set of timing parameters is selected from the drop-down 
menu, the timings shown in the 
Video Input Timing
 section are 
not updated until 
Load
 has been clicked. To view the timing 
values before loading them, check the 
Show Timing Values
 
check box. When the box is checked and a new entry is 
selected the values associated with the new entry will be 
displayed in the 
Video Input Timing
 section in red.
In the 
Video Input Timing
 section, click 
Edit
 to activate all input 
timing fields for modification. In Chapter 6, refer to the 
 command description for technical details on all 
input parameters. 
The parameters are:
HFP
Horizontal Front Porch
VFP
Vertical Front Porch
HSYNC
Horizontal Sync
VSYNC
Vertical Sync
HBP
Horizontal Back Porch
VBP
Vertical Back Porch
HACT
Horizontal Active
VACT
Vertical Active
Modified timing parameters can be saved using Save.
In the 
Interactive Adjustment
 section, controls are provided to 
enable qualified engineering personnel to interactively adjust 
input timing and input modulus parameters for the active screen 
area. Interactive adjustments can be used to fine tune the 
settings for non-standard video input signals.
Important
Only qualified engineering personnel should adjust or 
modify video input timing parameters.