Alarm In   
 
1 Alarm In Detect                                OFF
2 Configuration Table 2 
3 Exit 
Release Time 
 
1 Motion RES Time                                  2
2 Video Loss RES Time                          2
3 Alarm In RES Time                           
       
10
4 Exit 
Clear Event List 
 
1 Clear Event List: No 
2 Clear Event List: Yes 
3 Exit 
 
Motion Detect 
 
 
 
 
Threshold: Day 
 
 
  
Threshold: 
Night 
 
6.6.3.5 Sensetivity 
This item allows you to setup the threshold of motion detection. 
The first bar shows the current detected amount of motion of this 
camera. The second and third bar allows you to setup the “day/ night 
threshold” (or “trigger level”), once the detected motion amount 
become larger than this level; the alarm will be triggered. 
 
6.6.4 Alarm In 
This menu allows you to enable/ disable the Alarm pins of external I/O 
connector and to select N.O. (normal open) or N.C. (normal close) 
type for each pin.   
 
6.6.4.1 Alarm In Detect 
This item allows you to enable (YES) or disable (NO) the Alarm In pins. 
 
6.6.4.2 Configuration Table 2 
This item allows you to select N.O. (normal open) or N.C. (normal close) type for each Alarm In 
pins.  
 
6.6.5 Video Loss Detect   
This item allows you to enable/ disable the DVR-16/IP to detect Video Loss as an alarm event. 
 
6.6.6 Alarm Set/ Reset SW 
This item allows you to enable/ disable the Alarm Set/ Reset signal of the external connector. If 
you select EN (enable), then you can force the alarm output to on/ off by using Alarm Set signal. 
 
6.6.7 Release Time 
This menu allows you to set the “release time” of alarm source: motion 
detection, video loss and alarm in. The release time defines how long 
time after the alarm trigger condition disappears; the same condition 
should be ignored to avoid false alarm being re-triggered.   
 
6.6.8 Clear Event List 
This menu allows you to clear event list. If you want to delete the 
event list, move your cursor to 2 Clear Event List: YES. If you want to 
keep the event list, move your cursor to 1 Clear Event List: NO. 
This arrangement is to avoid user clear the list by mistake.