EMERGENCY AGENT OVERVIEW 
 
The Emergency Agent software is a utility that streams video across a Local Area Network to a Client PC when an alarm is detected 
on the DVR. The video that streams across can be stopped, played forwards and backwards, in slow motion or real speed.  
 
The utility is loaded at startup and placed in the taskbar. It constantly monitors for a signal from the DVR. When an alarm signal is 
detected the Emergency Agent Image Viewer window opens and starts playing the video from the camera associated to the alarm.  
 
 
Configuring the DVR  
 
To enable the Emergency Agent on the DVR follow these steps:   
 
1.  Enter Setup and confirm you are in the Camera Setup Menu.  
 
 
2.  Select a camera and then associate sensor(s) to that camera using the Sensor Connection Boxes. 
 
3.  Click the Network Setup button and make sure that Disable Remote Control is not checked. 
 
NOTE: The Emergency Agent uses one port to transfer the data through (the Emergency Port). The port can be adjusted inside the 
Network Setting Menu if necessary. It is recommended that the default setting should be used unless the port must be changed.  
 
4.  Click the Schedule Setup button. 
 
 
5.  Select the Sensor option to open the sensor schedule window. 
 
6.  Enter the IP Address of the computer running the Emergency agent 
software. 
 
7.  Click the box next to the IP Address to enable it. 
 
 
8.  Create a schedule for the appropriate sensor. 
 
 
9.  Highlight the sensor schedule blocks and click the [E] Emergency Agent 
button. 
 
 
NOTE: The DVR will not send alarm events to the Client PC if the sensor 
schedule does not have the Emergency Agent Alarm Option enabled. 
 
 
10.  Click Apply. 
 
 
Configuring the Client PC 
 
All configurations takes place in the Emergency Agent window on the Client PC.  For descriptions and locations of the buttons and 
features of the Emergency Agent window refer to the Emergency Agent window section later in this chapter. 
 
1.  Open the Emergency Agent window on the Client PC - Start >All Programs > Surveillix > Emergency Agent > Emergency Agent 
 
2.  Right-click in the DVR List and select New.  Enter the DVR Code, 
DVR Name, and IP Address of the DVR to connect to in the Site Edit 
window that opens. Click OK 
 
 
3.  From the Options menu, click Setup. 
 
4.  Confirm that the Network Port in the Setup window is set to the same 
number as the Emergency Port in Network Settings on the DVR. If 
the numbers are different adjust the Network Port on the client PC to 
match the DVR.  
 
5.  Click OK. 
 
6.  Restart the Client PC.