Справочник Пользователя для Speco Technologies PC Pro Series

Скачать
Страница из 136
 
119 
Alarm Setting 
In the Alarm Setting dialog box, click Add to insert and set new alarm setting, click Delete to 
remove the selected alarm setting, click OK to exit and save the setting, Cancel to exit without 
saving, and Default to revert back to original factory setting. 
(1)
(2)
(3)
(4)
(5)
(6)
(7)
 
To set the Alarm Setting:   
1. Click 
Add
 to insert and set a new alarm setting. Click the items in the (7) Alarm Setting List
if you want to modify the alarm setting. 
2. In 
(1) Alarm Setting number/Name/Description
, display the selected alarm setting number 
in the list below. Enter alarm name and description. 
3. In 
(2) Enable Time
, the number from 00 to 23 represent the time in 24-hour clock. Select the 
time and click the block you want to activate or deactivate the alarm function. When it is 
deactivated the color of the block turns white. 
4. In 
(3) Conditions
, you can set “Trigger if any” to activate if it falls to one of the conditions or 
Trigger if all” to activate if it falls to all conditions. 
In Camera section, select and click on the camera number (01 to 16) in Motion 
Detected
 and Video Loss to set the condition for the system to alarm. 
- In 
Missing and Suspicious Object Detected
, click the camera number (01 to 16) and 
select the certain object on the screen (right click on camera number for detailed 
setting)), and when the certain object is missing or doubtful, the system will alarm. (see 
also 
Chapter 4.9.12
) In Scene Change, when the camera has been moved, the system 
will alarm, too. 
- In 
Voice Detection
, click the camera number (01 to 16) to the system to alarm when 
detect the abnormal voice. 
5. In 
(4) Sensor
, select and click on the sensor number (use W and X to select the sensor) to 
set the condition for the system to alarm. If the sensor normal status is high, set the sensor 
condition to low (see 
Chapter 4.7 step #4 
). 
- Enable/disable 
the 
Abnormal Event 
check box, to set the condition of the event for 
system to alarm. 
• 
Normal Reboot:
 when the DVR system reboot without abnormal condition, the 
system will send out the alarm message. 
• 
Abnormal Reboot:
 when the DVR system reboot in irregular condition, the system 
will send out the alarm message. 
• 
Recording is switched off: 
when the recording has been stopped, the system will