Справочник Пользователя для Toshiba C-DR0101

Скачать
Страница из 56
N E T W O R K     S E T T I N G
I P     A D D R E S S
192.  16 8. 0 00.  001
S U B N E T     M A S K
255.  25 5. 2 55.  000
D E F A U L T     G A T E W A Y
000.  00 0. 0 00.  000
C O M M U N I C A T I O N     S E T T I N G
R S 2 3 2 C     B A U D     R A T E
[ 3 8 4 0 0 ]
R S 2 3 2 C   F L O W     C T R L
[ O F F ]
N E T W O R K     S E T T I N G
S W I T C H E R     S Y N C
[               O F F ]
23
• Pressing the Menu key after the setting displays the confirmation
message in the lower part of the screen if the entered IP address is
different from the current IP address. 
• Holding down the Select key for at least 1 second on the confirmation
message display screen displays the setting save screen. 
• Press the Menu key if performing no setting. The display returns to
the normal communication setting screen. 
N E T W O R K     S E T T I N G
I P     A D D R E S S
192 . 16 8. 0 00.  001
S U B N E T     M A S K
255 . 25 5. 2 55.  000
D E F A U L T     G A T E W A Y
000 . 00 0. 0 00.  000
S E T     T H I S     S E T T I N G .   O K ?
Y E S   :   S E L E C T     K E Y     1 S E C
N O   :   M E N U     K E Y
N E T W O R K     S E T T I N G
S A V I N G     S E T     D A T A     N O W .
P L E A S E     W A I T     F O R     A     W H I L E .
Setting Value
Contents
Setting Item
RS232C BAUD 
RATE
RS232C FLOW 
CTRL
SWITCHER SYNC
(Switcher 
Synchronization) 
*
1
Sets the transmission rate. 
Sets Flow Control RTS or CTS
ON :  Controls the switcher through the RS-232C interface.
OFF : Controls no switcher
TIME SYNC : Only Time Synchronization can be controlled through the
RS-232C interface.
9600 / 19200 / 38400 (bps)
ON / OFF
ON / OFF / TIME SYNC
7.8.1. Network Settings
The Network Setting screen is displayed if Network Settings is selected on the communication setting screen.
Perform settings that are appropriate for the network. 
• Move the cursor with the (
) or (
) key, and change setting values
with the (
) or (
+
) key.
* The underlined contents are factory-preset values. 
7.8.  Communication Settings
Set the transmission rate and whether or not to use flow control in RS-232C communications. Also set the IP
address, etc. to be used in the Ethernet network.
• Move the cursor with the (
) or (
) key, and change setting values
with the (
) or (
+
) key.  
• Confirm the setting with the Menu key, and return to the previous
screen.
Note
*
1
Recording Pattern, Motion Detection Pattern, Camera/ VCR mode selection, and Time Synchronization
switcher functions can all be controlled by the Digital Video Recorder. However, when syncronizing the
switcher's clock from the Recorder, set the Recorder's clock Time Synchronization setting to "MASTER."
Time synhronization cannot be performed if set to "SLAVE."