Справочник Пользователя для Toshiba C-DR0101

Скачать
Страница из 56
51
Command
BT
16.1.7. RS-232C Communication Command (Digital Recorder        Controller)
Commands are 2 bytes in length. Parameters (PARA) are also 2 bytes. They are followed by the multi-byte
DATA section.
Key response command
Operation
0:Power OFF, 1:Power ON
0:Standby or Stop
1:Pause
2:Playback
3:Fast Forward Playback
4 Reverse Playback
5:Rewind
6.Menu or Search Screen Display
7:Disk Error or disk operation such as disk recognition
0:Standby or Stop
1:Recording
2:Alarm Recording
3:Internal Timer Recording
0: No failure
1: Hard disk failure
2: Video loss failure
3: Fan failure
PARA
QT
DATA LEN
1
1
1
1
Contents
Operation Status
Status
Recording Status
Failure
16.1.6. RS-232C Communication Format (Digital Recorder         Controller)
STX : 
Fixed to A0H.
LEN : 
The number of bytes from command to DATA
COMMAND :  BT, MV, LG
PARA : 
Parameter
DATA : 
DATA section (variable depending on a command and parameter)
ETX : 
Fixed to AFH.
STX
LEN
COMMAND
PARA
DATA
ETX
Item
1
1
2
2
Variable
1
No. of Byte