Connecting PMS and printers using TCP/IP
Issue 4   October 2002
227
555-233-116
4. Establish a physical connection from the data port on the circuit pack, 
through the MDF, to the wall jack where the data unit is installed.
5. Connect the data modules to the equipment.
Using an asynchronous data unit (ADU)
and a data line circuit pack
You connect an asynchronous data terminal through an ADU to a data line circuit 
pack. Normally, the connected data terminal powers the data unit. The data unit 
can also be remotely or locally powered using a 2012D transformer with a 248B 
adapter. Data units connected to receive-only printers require external power.
1. Configure printer or terminal in accordance with the recommendations in 
the vendor’s documentation.
2. Identify the port associated with the data unit or data module using the 
Data Module Form (see 
).
3. Establish a physical connection from the data port on the circuit pack, 
through the MDF, to the wall jack where the data unit is installed.
4. Connect the information outlet to the ADU.
5. Connect the RS-232 plug on the ADU or data module to the data terminal.
6. Connect the printer to the ADU using a modem or data module, following 
the instructions in 
, an
Connecting PMS and printers using 
TCP/IP
Property management systems (PMS) and printers can be connected to the 
switch using asynchronous TCP/IP links. This section provides information on 
connecting these adjuncts to the C-LAN and performing the initial administration.
Task list
Whether you use an end-to-end TCP/IP configuration, a terminal server or a PC 
running RSP, you must complete the following tasks:
.
If you are using a terminal server, also complete 
If you are using a PC with the Downloadable RSP Tool, complete