Distance Limitations
The maximum allowable distances of a 2500 telephone from the DEFINITY G1, G2, G3, System
75, or System 85 cabinet are shown in the table below.
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
NOMINAL MAXIMUM RANGE
IN FEET (METERS)
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
SYSTEM
PORT BOARD
24 AWG
26 AWG
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
SYSTEM 85
SN229
3,500 (1,067)
3,500 (1,067)
SN228B
15,000 (4,572)
9,000 (2,743)
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
DEFINITY G2
SN229
3,500 (1,067)
3,500 (1,067)
SN228B
15,000 (4,572)
9,000 (2,743)
TN742
20,000 (6,100)
13,000 (3,962)
TN746
3,100 (945) 
2,000 (610)
TN746B
3,100 (945) 
2,000 (610)
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
DEFINITY G1 & G3
TN742
20,000 (6,100)
13,000 (3,962)
SYSTEM 75
TN769
20,000 (6,100)
13,000 (3,962)
TN746
3,100 (945) 
2,000 (610)
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
cc
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
cc
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
cc
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
cc
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
Power Requirements
Both 2500 telephones are powered by the tip and ring leads. These telephones do not require
any external power supply.
Switch Administration
Both 2500 telephones must be administered in the following ways:
d
If the 2500 MMGL or 2500 YMGL telephone is connected to a System 75 or DEFINITY
G1 or G3, it must be administered as a 2500 analog telephone.
d
If either of the 2500 telephones is connected to a System 85 or DEFINITY G2, it can be
administered as an analog line.
Power Failure Operation
Both 2500 telephones can be used as an emergency station during power failure transfer condi-
tions.