Lamp Replacement
The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or 
sooner if a noticeable degradation in brightness occurs. When you replace a lamp, you 
should replace the filters as well. 
For lamp or filter replacement, please contact your nearest Vidikron authorized service 
center or Vidikron dealer. Do not attempt to replace the lamp yourself!
1.
Turn off the projector and unplug the power cord. Allow the projector to cool down for 
approximately 45 minutes prior to removing the lamp assembly for replacement.
2.
Loosen and remove the rear Lamp Cover screw.  
 
 
 
 
3.
Slide the Lamp Cover in the direction of the arrow 
to remove it. 
 
 
4.
Loosen the two, captive lamp assembly mounting 
screws using a coin or a large, flat-blade 
screwdriver.  
 
 
5.
Grasp the lamp assembly handle and pull gently, 
removing the lamp module from the projector 
housing.
 
 
 
5
Maintenance and Troubleshooting
The Vision 120 lamp is under high pressure. Handle it with great care at 
all times. Lamps may explode if dropped or mishandled. 
Never attempt to disassemble the lamp casing or dispose of the lamp 
casing in any manner other than by returning it to your Vidikron dealer.
If the lamp breaks, leave the area immediately and stay away for at least 
30 minutes. Ventilate the room to allow the mercury vapor to disperse.
If you inhale the mercury vapor, see a physician immediately.
WARNING