Справочник Пользователя для Sharp PGLW2000

Скачать
Страница из 75
58
4
  Remove the lamp unit. 
Loosen the securing screw from the lamp 
unit. Hold the lamp unit and pull it in the 
direction of the arrow. At this time, keep 
the lamp unit horizontal and do not tilt it.
5
  Insert the new lamp unit.
Press the lamp unit fi rmly into the lamp unit 
compartment to align the lamp connectors. 
Fasten the securing screw.
6
  Replace the lamp unit cover.
Slide the lamp unit cover horizontally back 
into place and align the tabs (1). Then 
tighten the user service screw (2) to 
secure the lamp unit cover.
Info
If the lamp unit and lamp unit cover 
are not correctly installed, the power 
will not turn on, even if the power 
cord is connected to the projector.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp. 
Info
Make sure to reset the lamp timer only when 
replacing the lamp. If you reset the lamp timer 
and continue to use the same lamp, this may 
cause the lamp to become damaged or 
explode.
1
  Connect the power cord.
Plug the power cord into the AC socket of 
the projector.
2
  Reset the lamp timer.
While simultaneously holding down 
MENU, ENTER and 
R
 on the projector, 
press STANDBY/ON on the projector and 
keep all four buttons pressed down until 
the lamp indicator starts blinking green.
“LAMP 0000H” is displayed, indicating 
that the lamp timer is reset.
4
5
 
6
 
AC socket
AC socket
1
ENTER button
MENU button
R button
STANDBY/ON 
button
ENTER button
MENU button
R button
STANDBY/ON 
button
2
 
Regarding the Lamp (Continued)
Securing
screw