Problem
Check
Page
3D images fl icker when 
watching in a room.
Images may appear to fl icker when fl uorescent light or ambient light 
enters your vision.
Turn off the lights.
Block any ambient light.

Ghosting (a double image) 
occurs without the image 
appearing in 3D.
Check that you are using 3D LCD shutter glasses that support the 
DLP
®
 Link™ system.
Be sure to use 3D LCD shutter glasses that support the DLP
®
 Link™ 
system.
Check that the shutters on the 3D LCD shutter glasses are working 
properly.
Turn the 3D LCD shutter glasses off and then on again.
Check the batteries of the 3D LCD shutter glasses.
Check that the 3D LCD shutter glasses are set to 3D viewing mode.
Some 3D LCD shutter glasses are equipped with a special viewing 
mode (such as “dual view mode”) in addition to the normal 3D 
viewing mode. See the operation manual of your 3D LCD shutter 
glasses.


Check the settings of the projector.
Turn the DLP
®
 Link™ function “On”.
Use “DLP
®
 Link™ Invert” to change the setting.

Check whether a signal that is not supported is being input.
Confi gure your 3D application at the correct resolution and refresh 
rate. 
Make sure you are running your 3D application in resolutions that 
support 3D. To support 3D, your 3D application must be confi gured 
to run at the correct settings for this projector.
For details on the supported signals, see “3D Supported Signals” of 
the Compatibility Chart.
If the projector is connected to a computer for 3D image playback, 
check that a stereoscopically-enabled application is being used.
Use the applicable software.
Set the applicable software to the fi eld sequential format.

Check that there are no obstructions between the screen and the 3D 
LCD shutter glasses.
Remove any obstructions.
Any obstructions may cause the glasses not to function properly 
causing the lenses to fl icker or turn off. Do not place your hand or 
other objects in front of the 3D control signal sensor on the glasses.
Check whether there is a source of high intensity lighting nearby.
Block the light or turn it off.
High intensity lighting can interfere with communication between the 
3D LCD shutter glasses and the screen resulting in some fl icker.
Check whether two or more projectors are projecting 3D images at the 
same time.
Use only one projector at a time.
This unit is equipped with a microprocessor. Its performance could be adversely affected by incorrect 
operation or interference. If this should happen, unplug the Unit and plug it in again after more than 5 
minutes.