8   PROGRAMMING 
MELSEC-QnA 
 
8.4 Link Special Relay/Register (SB/SW) 
The data link status can be checked with bit data (link special relay SB) and word data 
(link special register SW). 
The SB and SW are used to conveniently express the information on the buffer 
memory of the master and local modules. They are read and written before use with 
FROM/TO instructions. 
• Link special relay (SB).................. Buffer memory address 5E0
H
 to 5FF
H
 
• Link special register (SW) ............ Buffer memory address 600
H
 to 7FF
H
 
 
8.4.1 Link special relay (SB) 
SB0000 to SB002F is turned on/off with the sequence program, and SB0030 to 
SB00FF is automatically turned on/off. 
Refer to Section 3.5.2 (4) for correspondence with buffer memory. 
When using a master/local module as a standby master station, refer to the respective 
columns under "Availability" in the table as explained below. 
• When a standby master station is operating as a master station: "Master station" 
column 
• When a standby master station is operating as a standby master station: "Local 
station" column 
 
Table 8.1 Link special relay list 
 
Availability  
(  : available,  
   : not available )
Online 
Number Name 
Description 
Master 
station 
Local 
station
Offline
SB0000 Data 
link 
restart 
When parameter data change is not made to the data link which was 
stopped by SB0002, restart it with this signal. (If you have changed 
parameter data during a data link stop, turn on Yn6 and Yn8 to restart a 
data link.) 
OFF  : No restart specification 
ON  : Restart specification 
 
 
 
SB0001 1 
Master station switching 
data link start 
The output information is switched from the standby master station to 
the master station to start the data link (Usable in standby master 
station). 
OFF  : No switch instruction 
ON  : Switch instruction 
 
 
 
SB0002 
Data link stop 
Stops the host station's data link. 
However, when the master station executes this, the entire system 
stops. 
OFF  : No stop specification 
ON : 
Stop 
specified 
 
 
 
SB0004 1 
Temporary error invalid 
station request 
Confirms the station which had been specified by SW0003 to SW0007 
to temporary error invalid station. 
OFF : No request 
ON : 
Request 
 
 
 
SB0005 1 
Temporary error invalid 
station cancelling request 
Cancels the station which had been specified by SW0003 to SW0007 
from temporary error invalid station. 
OFF : No request 
ON : 
Request 
 
 
 
SB0008 1 Line 
test 
request 
Performs the line test to station which had been specified by SW0008. 
OFF : No request 
ON : 
Request 
 
 
 
SB0009 1 
Parameter setting test 
request 
Reads the parameter setting information for actual system 
configuration. 
OFF : Requested 
ON  : Not requested 
 
 
 
1: Link special relay added to the function version B or later