10 - 13 
10   COMMUNICATION BETWEEN THE MASTER STATION AND THE 
REMOTE DEVICE STATION 
MELSEC-QnA 
 
10.3.2 Confirming the operation by the program 
Using the sequence program, confirm that the data link is proceeding normally. 
 
1
 The digital value which was converted by AJ65BT-64AD is stored in D210 (CH1 
digital value) and D211 (CH2 digital value). 
2
 When X60 is turned on, the output voltage appears on CH1 of AJ65BT-64DAV. 
 
AY42
AX42
X60
AJ61
QBT11
AY41
AX41
Q3ACPU
A62P
AJ65BT-64AD
AJ65BT-64DAV
D210
D211
ON
Terminating resistor
Master station
CH2 digital value
CH1 digital value
A/D conversion by AJ65BT-64AD
Occupies 2 stations
Remote device station
(station No.1)
A/D conversion module
Voltmeter
Occupies 2 stations
Remote device station
(station No.3)
D/A conversion module
Terminating 
resistor
1
2
1
2