Справочник Пользователя для Mitsubishi Electronics A1SJ61BT11

Скачать
Страница из 294
 
 
 
13 - 16 
MELSEC-QnA 
13   TROUBLESHOOTING 
 
13.4.9 When the transmission speed is set incorrectly 
This is a case where the transmission speed for the remote device station is set 
incorrectly. 
The "L RUN" LED for the remote device station with the incorrect transmission-speed 
setting turns off. 
 
A
J61QBT11
B
R
A
T
E
156K
625K
2.5M
5M
10M
TEST
S0
S1
S2
T
E
S
T
E
R
R
O
R
A
J61QBT11
B
R
A
T
E
156K
625K
2.5M
5M
10M
TEST
S0
S1
S2
SD
RD
T
E
S
T
E
R
R
O
R
PW L RUN
L ERR. 
SD
RD
SD
RD
RUN 
L RUN 
L ERR. 
PW
SD
RD
Power
supply
Master
station
Stabilized power
supply (24VDC)
Terminating
resistor
Stabilized power
supply (24VDC)
Local 
station
Power
supply
Terminating
resistor
    ................. indicates the "light-on" status. 
    ................. indicates the "light-off" status. 
    ................. indicates the "flashing" status. 
    ................. indicates one of the "light-on", 
                      "light-off" or "flashing" status.
RUN 
ERR. 
MST 
S MST
LOCAL
CPU R/W 
SW
M/S
PRM 
TIME
LINE 
L RUN 
L ERR. 
RUN 
ERR. 
MST 
S MST
LOCAL
CPU R/W 
SW
M/S
PRM 
TIME
LINE 
L RUN 
L ERR. 
Remote I/O
station
Remote device
station
Programmable
controller CPU
Programmable
controller CPU
 
 
13.4.10 When the switch setting is changed during data link 
This is a case where the switch setting for the remote I/O station was changed. 
The "L ERR." LED for the remote I/O station whose switch setting was changed 
flashes. However, data link can be continued. Also, if returned to the previous state,  
"L ERR." turns off. 
 
A
J61QBT11
B
R
A
T
E
156K
625K
2.5M
5M
10M
TEST
S0
S1
S2
T
E
S
T
E
R
R
O
R
A
J61QBT11
B
R
A
T
E
156K
625K
2.5M
5M
10M
TEST
S0
S1
S2
SD
RD
T
E
S
T
E
R
R
O
R
PW L RUN
L ERR. 
SD
RD
SD
RD
RUN 
L RUN 
L ERR. 
PW
SD
RD
Power
supply
Master
station
Stabilized power
supply (24VDC)
Terminating
resistor
Stabilized power
supply (24VDC)
Local 
station
Power
supply
Terminating
resistor
    ................. indicates the "light-on" status. 
    ................. indicates the "light-off" status. 
    ................. indicates the "flashing" status. 
    ................. indicates one of the "light-on", 
                      "light-off" or "flashing" status.
RUN 
ERR. 
MST 
S MST
LOCAL
CPU R/W 
SW
M/S
PRM 
TIME
LINE 
L RUN 
L ERR. 
RUN 
ERR. 
MST 
S MST
LOCAL
CPU R/W 
SW
M/S
PRM 
TIME
LINE 
L RUN 
L ERR. 
Remote I/O
station
Remote device
station
Programmable
controller CPU
Programmable