14 - 1 
MELSEC-QnA 
14   OVERVIEW (FUNCTION VERSION B OR LATER) 
 
 
 
 
 
 
 14
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
14. OVERVIEW (FUNCTION VERSION B OR LATER) 
The functions available with the master and local modules depend on their function 
versions and CPU types, as shown in Table 14.1. 
 
Table 14.1 List of available functions with different function versions 
Function version 
Function Description 
Detailed 
description 
B or later
CPU module 
Sets parameters from a peripheral device as a part of CPU parameters 
and notifies when the power is turned on or status is changed from 
STOP   RUN. 
– 
 
2 3
Buffer memory 
The method to write directly into the buffer memory in the module and 
receive notification. 
 
 
Parameter registration 
E
2
PROM 
The method to register to the E
2
PROM in the module and receive 
notification. 
 
 
Automatic refresh 
Cyclic transmission data, such as RX and RY, can be refreshed to a 
desired device by the END processing specified from a peripheral 
device. 
– 
 
2 3
Synchronous mode 
Data link can be performed using the scan synchronized with the 
sequence program. 
– 
 
2 3
Scan synchronization 
Asynchronous mode 
Data link can be performed using the scan not synchronized with the 
sequence program. 
 
 
Bit transmission 
Data communication can be performed at 32 points per station. 
 
 
Cyclic transmission 
Word transmission 
Data communication can be performed at 4 points per station. 
 
 
Transient transmission can be performed to the intelligent device and 
local station using dedicated instructions. 
– 
 
1 3
Dedicated instructions 
Device read/write with respect to the CPU in the specified station is 
possible using dedicated instructions. 
– 
 
1 3
Transient transmission 
Communication 
instruction 
Data communication with other stations is possible. 
Data read/write with other stations is also possible. 
– 
 
1 3
Remote I/O net mode 
Communication can be performed only with the remote I/O station 
without setting parameters. 
– 
Reserved station setting 
Stations to be connected later can be skipped and set in advance. 
 
 
Error detection invalid station setting 
Data link error can be ignored when data link is disabled at any station. 
 
 
Temporary error invalid station setting 
Replacement of modules can be performed online without detecting an 
error at the corresponding remote station. 
– 
 
Module reset 
Only CC-Link can be reset when changing switches, etc., without 
stopping the CPU. 
 
 
Data link stop/restart 
Stop/restart can be performed during data link. 
 
 
Automatic return 
The station which has been disconnected from data link can be 
returned automatically to the data link through normal return. 
 
 
Standby master 
Data link can be continued when an error occurs at the master station, 
by switching to the standby master station. 
– 
 
Slave station 
disconnection 
The station at which data link has been disabled can be disconnected 
so that data link can be continued using normal stations only. 
 
 
Confirmation of data 
link status 
The data link status can be confirmed using the special relay and 
special register. 
 
 
Off-line test 
A hardware test, line test, etc., can be performed. 
 
 
On-line test 
Line testing and control of link such as starting up and stopping can be 
performed from a peripheral device. 
RAS 
Monitor/diagnosis 
Monitoring and diagnosing can be performed from a peripheral device.