15 - 11 
MELSEC-QnA 
15   FUNCTIONS (FUNCTION VERSION B OR LATER) 
 
15.6 Dedicated Instructions 
Transient transmission can be performed to the intelligent device station and local 
station using dedicated instructions. 
Dedicated instructions also facilitate read/write of data with handshake from/to remote 
devices. 
The dedicated instructions that can be used from different types of stations are shown 
in Table 15.6. Refer to the QnACPU Programming Manual (Special Function Module) 
for the detail of each instruction. 
 
Table 15.6 List of available dedicated instructions at different stations 
Availability (  : available,   : not available) 
Applicable station  Instruction 
Description 
Master station 
Local station 
Standby master 
station 
CCL 
CCLEND 
Registers mail box for intelligent device and remote 
device instructions 
 
 
 
SPCCLR 
Issues an interruption instruction to the intelligent 
device instruction. 
 
 
 
SPCBUSY 
Reads status of remote station. 
 
 
 
Reads data in the buffer memory of the specified 
station. 
 
 
 
RIRD 
Reads device data in the CPU of the specified 
station. 
 
 
 
Writes data into the buffer memory of the specified 
station. 
 
 
 
Master station, 
local station 
RIWT 
Writes data into the CPU of the specified station. 
 
 
 
RIRD 
Reads contents in the buffer memory of the 
specified station. 
 
 
 
RIWT 
Writes data into the buffer memory of the specified 
station. 
 
 
 
RISEND 
Writes data with handshake into the buffer memory 
of the specified station. 
 
 
 
RIRCV 
Reads contents with handshake in the buffer 
memory of the specified station. 
 
 
 
RIFR 
Reads contents in the automatic refresh buffer of 
the specified station.  
(Random access buffer can be specified.) 
 
 
 
Intelligent device 
station 
RITO 
Writes data into the automatic refresh buffer of the 
specified station.  
(Random access buffer can be specified.) 
 
 
 
 It can be used with software version J (manufactured in Jan., 1998) or later. 
 
POINT 
 
(1) Execute the dedicated instructions during data link. 
If any of them is executed in the offline mode, an error does not occur but the dedicated 
instruction is not completed. After changing the offline mode to the online mode, reset the 
CPU. 
(2) Since the dedicated instructions use the last two bits of RX/RY of the target station as a 
handshake signal, do not execute write using the TO instruction, etc. during execution of 
any of the dedicated instructions.