Справочник Пользователя для Mitsubishi Electronics A1SJ61BT11

Скачать
Страница из 294
 
 
 
APPX - 3 
MELSEC-QnA 
APPENDICES 
 
Appendix 2 Parameter Setting Sheet 
Item Setting 
range 
Buffer memory 
address 
Remark 
Default value  Setting value
Number of linked 
modules 
1 to 64 
1
H
 – 64 
 
Number of retries 
1 to 7 
2
H
 – 3 
 
Number of automatic 
return modules 
1 to 10 
3
H
 – 1 
 
Standby master station 
specification 
0 to 63  
(0: No specification) 
4
H
 – 0 
 
Operation when CPU 
down 
0: stop 
1: continue 
6
H
 – 
(stop) 
 
Delay time setting 
Set 0. 
8
H
 – 0 
 
10
H
 
Station No. 16 to 1 
0000
H
 
 
11
H
 
Station No. 32 to 17
0000
H
 
 
12
H
 
Station No. 48 to 33
0000
H
 
 
Reserved station 
specification 
Turn on the corresponding 
bit for station to reserve. 
13
H
 
Station No. 64 to 49
0000
H
 
 
14
H
 
Station No. 16 to 1 
0000
H
 
 
15
H
 
Station No. 32 to 17
0000
H
 
 
16
H
 
Station No. 48 to 33
0000
H
 
 
Invalid station 
specification 
Turn on the corresponding 
bit for station to invalidate. 
17
H
 
Station No. 64 to 49
0000
H
 
 
20
H
 1st 
module 
0101
H
 
 
21
H
 2nd 
module 
0102
H
 
 
22
H
 3rd 
module 
0103
H
 
 
23
H
 4th 
module 
0104
H
 
 
24
H
 5th 
module 
0105
H
 
 
25
H
 6th 
module 
0106
H
 
 
26
H
 7th 
module 
0107
H
 
 
27
H
 8th 
module 
0108
H
 
 
28
H
 9th 
module 
0109
H
 
 
29
H
 10th 
module 
010A
H
 
 
2A
H
 11th 
module 
010B
H
 
 
2B
H
 12th 
module 
010C
H
 
 
2C
H
 13th 
module 
010D
H
 
 
2D
H
 14th 
module 
010E
H
 
 
2E
H
 15th 
module 
010F
H
 
 
2F
H
 16th 
module 
0110
H
 
 
30
H
 17th 
module 
0111
H
 
 
31
H
 18th 
module 
0112
H
 
 
32
H
 19th 
module 
0113
H
 
 
33
H
 20th 
module 
0114
H
 
 
34
H
 21st 
module 
0115
H
 
 
35
H
 22nd 
module 
0116
H
 
 
36
H
 23rd 
module 
0117
H
 
 
37
H
 24th 
module 
0118
H
 
 
38
H
 25th 
module 
0119
H
 
 
39
H
 26th 
module 
011A
H
 
 
3A
H
 27th 
module 
011B
H
 
 
Station information 
b15 to b12 (station type) 
0: remote I/O station 
1: remote device station 
2: intelligent device station, 
local station 
 
b11 to b8 (number of 
occupied stations) 
1: occupies one station 
2: occupies two stations 
3: occupies three stations 
4: occupies four stations 
 
b7 to b0 (station number) 
01
H
 to 40
H
 (1 to 64) 
3B
H
 28th 
module 
011C
H