2-8 Wiring of the peripheral control
2 - 37
2-8-2 Wiring of the contactor control
(1) Output circuit of contactor control
A relay or photo coupler can be driven. When using an inductive load, install a diode.
(Tolerable current: 40mA or less, rush current: 100mA or less)
(2) Parameter setting
Set the following parameters for the contactor control axis.
#2282   SV082  SSF5  Servo function 5
bit B-A:dos3 Digital signal output 3 selection
bitB,A=
00: Disable
01:Setting prohibited
10:Contactor control output (For MDS-D-SVJ3)
11:Setting prohibited
#13227   SP227  SFNC7  Spindle function 7
bit B-A:dos3 Select the digital signal output 3
bitB,A= 
00: Disable
01:Setting prohibited
10:Contactor control output (For MDS-D-SPJ3)
11:Setting prohibited
3  DOCOM
5  DICOM
 
15 
MC
CN9
MDS-D-SVJ3/SPJ3
24VDC
Contactor
Contactor control relay
(There are also types that
are built into the contactor.)
The servo drive unit will fail