Справочник Пользователя для Mitsubishi Electronics IB-1500193(ENG)-D

Скачать
Страница из 528
3 - 3
MDS-D-SVJ3/SPJ3 Series Instruction Manual
3-1 Initial setup
3-1-2 Setting DIP switch
Setting the DIP switches is necessary prior to turning ON the power. Setting of the DIP switches at the time 
of turning ON the power is validated. The DIP switches shall be as the standard setting (all the switches 
OFF). 
3-1-3 Transition of LED display after power is turned ON
When CNC, each drive unit power have been turned ON, each unit will automatically execute self-diagnosis 
and initial settings for operation, etc. The LEDs on the front of the units will change as shown below 
according to the progression of these processes.
If an alarm occurs, the alarm No. will appear on the LEDs. Refer to section "LED display when alarm or 
warning occurs" for details on the alarm displays.
Always input emergency stop when starting the servo system.
The switches are OFF when facing bottom as illustrated.
Setting unused axis
Unused axis can be set by turning the switches ON.
Waiting for NC
power start up
NC power ON
Drive units
LED display
Drive unit initialization complete
Waiting for NC power start up
NC power ON
Executing initial
communication with NC
Emergency stop state
The LED will alternate between
F#→E7→not lit.
(# is the set axis No.)
Servo ON state
Servo OFF sate
Repeats lighting and going out.
(1st axis in the display example)
NC power OFF
CAUTION