Справочник Пользователя для Mitsubishi Electronics FX

Скачать
Страница из 382
Introduction 1
1-4
1.5
Special considerations for programming equipment
1.5.1
FX CPU version 3.07 or later and FX
2C
 
Example usage
This format is very important for the instruction to operate
correctly.The user must program the ’mimic’ instruction
with the modifying M coil in a SET instruction immediately
before the instruction to be modified.
Peripherals Table
Description
Model Number
System software version which will.......
....require the use of
auxiliary M coils
....program all instructions 
directly
Hand held
programmer (HHP)
FX-10P-E
V 1.10
from V 2.00
HHP cassette
FX-20P-MFXA-E
V 1.20
from V 2.00
Programming
software
FX-PCS/AT-E-KIT
V 1.01
from V 2.00
FX-A6GPP-E-KIT
V 1.00
from V 2.00
Data access units
FX-10DU-E
V 1.10
from V 2.00
FX-20DU-E
V 1.10
from V 2.00
Other DU units
from V 1.00
Existing Instruction And Special M Coil Combination To Mimic The Operation Of The
Identified Instruction
Existing FX instruction
 used to mimic the operation of......
Mnemonic FNC number Modifying M coil
Mimicked instruction
Mnemonic FNC Number
MOV
12
M8190
Square root
SQR
48
MOV
12
M8191
Float
FLT
49
RAMP
67
M8193
Data search
SER
61
RAMP
67
M8194
RS232 instruction
RS
80
FMOV
16
M8196
Hex to ASCII conversion
ASCI
82
FMOV
16
M8197
ASCII to Hex conversion
HEX
83
FMOV
16
M8195
Sum check
CCD
84
FX
0(S)
FX
0N
FX FX
(2C)
FX
2N(C)
Programming tools operating old system software can not access the new features added to
the FX CPU from version 3.07 (and available on all FX
2C
 units). However, programming
certain ‘standard’ applied instructions in conjunction with special auxiliary coils (M coils) can
achieve the same ’effective instruction’ as the new instructions. The following tables identify
which version of peripheral software will work directly with all of the ’new’ features and which
peripheral software versions require use of modified instructions.
D10
K36
SET M8190
D10
K36
SQR
MOV
Using existing FX functions......
to mimic......