Справочник Пользователя для Mitsubishi Electronics FX

Скачать
Страница из 382
FX Series Programmable Controller
Diagnostic Devices 6
6-11
6.11
High Speed Zone Compare
Table Comparison Flags
(M8130 to M8139 and D8130 to D8139)  
For symbol key see page 6-1
Diagnostic
Device
Operation
Diagnostic
Device
Operation
M8130
Selects comparison tables 
to be used with the HSZ 
instruction
D8130 (
)(
)
Contains the number of the 
current record being pro-
cessed in the HSZ compari-
son table
M8131 (
)(
)
Identifies when the HSZ 
comparison table has been 
processed.
D8131 (
)(
)
Contains the number of the 
current record being pro-
cessed in the HSZ compari-
son table when the PLSY 
operation has been enabled
M8132
Selects the use of the PLSY 
instruction with the HSZ 
comparison tables
D8132 (
)(
)
Contains the source (output 
pulse frequency) data for the 
PLSY instruction when used 
with the HSZ comparison 
table
M8133 (
)(
)
Identifies when the HSZ 
comparison table (when 
used with the PLSY instruc-
tion) has been processed.
D8133
Reserved
M8134-
M8139
Reserved
D8134
D8135
(
) (
)
Contains a copy of the value 
for the current comparison 
when the HSZ comparison 
table and combined PLSY out-
put are used. This data is only 
available in 32 bit or double 
word format.
D8136
D8137
(
) (
)
Contains the total number of 
pulses that have been output 
using the PLSY (or PLSR) 
instruction. This data is only 
available in 32 bit or double 
word format
D8138 -
D8139
Reserved
D8140
D8141
(
) (
)
(FX
2N(C)
 only)
Contains the total number of 
pulses that have been output 
to Y0 using the PLSY or PLSR 
instructions. This data is only 
available in 32 bit or double 
word format.
D8142
D8143
(
) (
)
(FX
2N(C)
 only)
Contains the total number of 
pulses that have been output 
to Y1 using the PLSY or PLSR 
instructions. This data is only 
available in 32 bit or double 
word format.
FX
0(S)
FX
0N
FX FX
(2C)