FX Series Programmable Controller
Diagnostic Devices 6
6-15
6.16
Error Code Tables
Error Detection
Device
Stored Error
Number
Associated Meaning
Action
D8061
PLC Hardware 
error
0000
 No error
Check the cable connec-
tion between the pro-
gramming device and 
the PLC
6101
RAM error
6102
Operation circuit error
6103
I/O bus error (M8069 = ON)
6104
Extension unit 24V failure (M8069=ON)
6105
Watch Dog Timer error
Program execution time 
has exceeded the WDT 
time value set in D8000.
Error Detection
Device
Stored Error
Number
Associated Meaning
Action
D8062
PC/HPP
communica-
tions error
0000
No error
Check the cable connec-
tion between the pro-
gramming device and 
the PLC
6201
Parity/ overrun/ framing error
6202
Communications character error
6203
Communication data sum check error
6204
Data format error
6205
Command error
Error Detection
Device
Stored Error
Number
Associated Meaning
Note
D8063
Serial communi-
cation errors
0000
No error
Check both power and 
communications con-
nections
Special note regarding 
the 485 network:
Because these errors 
are not transmitted 
through the network, 
they must be monitored 
by the unit acting as 
Master to the network
6301
Parity/ overrun/ framing error
6302
Comms character error
6303
Comms data sum check error
6304
Comms data format error
6305
Command error
485 Network - received command other 
than GW (global) when station number 
was FF
6306
Watchdog timer error
6312
Parallel link character error
6313
Parallel link data sum check error
6314
Parallel link data format error
FX
0(S)
FX
0N
FX FX
(2C)
FX
2N(C)