5 Version Information and Peripheral Equipment Connectability
5.2 Programming Tool Applicability
5.1.2
Version check method
The PLC version number can be checked by reading the last three digits of device D8001/D8101.
5.1.3
Version upgrade history
FX
3S
 Series performed the following upgrade.
5.2
Programming Tool Applicability
5.2.1
Applicable versions of programming tool
1. GX Works2
GX Works2 is applicable to FX
3S
 PLCs from the following versions.
2. FX-30P
FX-30P is applicable to FX
3S
 PLCs from the following version.
5.2.2
In the case of programming tool (version) not applicable
Inapplicable programming tools can be used by selecting an alternative PLC model.
1. Alternative model setting
*1.
"FX
2N
" is selected when the FX-10P(-E) is used.
2. Contents of restrictions
• Programming is enabled only in the function range such as instructions, device ranges and program sizes 
available in both the FX
3S
 PLC and the PLC selected as the alternative model.
• When the FX-10P(-E) is used, the function range such as instructions, device ranges and program sizes is 
limited to that available in both the FX
3S
 PLC and the FX
2N
 PLC.
• Use a programming tool that can select either FX
3G
 to change parameters, i.e. memory capacity, file 
register capacity, etc.
• Memory capacity must be set to 4000 steps or less.
• Use a programming tool that can select the FX
3G
 model to program using the built-in USB port.
Version
Manufacturer's serial number
Contents of version upgrade
Ver. 1.00
133****
(March, 2013)
First product
Ver. 1.10
13X****
(October, 2013)
FX
3S
-30M/E-2AD (First product)
Supports connection of following expansion boards:
FX
3G
-4EX-BD, FX
3G
-2EYT-BD
Ver. 1.20
14X****
(October, 2014)
Supports connection of display module (FX
3S
-5DM).
FX
3S
 PLC version
Applicable GX Works2 version
Ver. 1.00
Ver. 1.492N or later
FX
3S
 PLC version
Applicable FX-30P version
Ver. 1.00
Ver. 1.50 or later
Model to be programmed
Model to be set
Priority High 
 Low
FX
3S
 PLC
FX3S
FX3G
FX1N
*1
FX2N
*1
D8001/D8101
PLC type and
version
2
8
1
0
0
Version information (Example: Ver. 1.00)
PLC type (Example: 28=FX