Справочник Пользователя для Mitsubishi Electronics FX3S-5DM

Скачать
Страница из 216
Appendix A: Special Device List
193
FX
3S
 Series Programmable Controllers
User's Manual - Hardware Edition
11
Bui
lt-
in Anal
og
12
O
utpu
t Wi
ring
13
Wiri
ng for
Va
rious U
ses
14
Te
st R
un,
M
ain
tenanc
e,
Troub
le
shooting
15
Oth
er Ex
tensi
on
U
nit
s and
Opti
ons
16
Displ
ay
 Modul
(FX
3S
-5
D
M
)
17
Me
m
ory
C
ass
ette
A
Spec
ial D
evices 
(M
8000-,
 D8000-)
B
Instruc
tion Li
st
C
Di
sc
onti
nued
model
s
Appendix A-2 Special Data Register (D8000 to D8511)
Appendix A-2 Special Data Register (D8000 to D8511)
*1.
“4” is displayed even when the memory capacity is
set to 16 K steps in the parameter setting.
*2.
D8003 becomes the undermentioned content.
*3.
Indicated value includes waiting time of constant
scan operation (when M8039 is activated).
*4.
The values of Z1 to Z7 and V1 to V7 are stored in
D8182 to D8195.
*5.
FX
3S
-30M/E-2AD is not supported.
*6.
Executed at END instruction.
Number and name
Content of register
Correspond-
ing special 
device
PLC status
 D 8000
Watchdog timer
Default value is 200 ms
(in 1 ms steps)
(Writes from system ROM at power
ON)
Value overwritten by program is
valid after END or WDT instruction
execution.
-
[D]8001
PLC type and 
system version
D8101
[D]8002
Memory capacity
2...2 K steps
4...4 K steps
*1
D8102
[D]8003
Memory type
Stores the memory type (built-in
EEPROM or memory cassette) and
the PROTECT switch ON/OFF
status of the memory cassette.
*2
-
[D]8004
Error number M
M8004
[D]8005 to [D]8009 Not used
-
Clock
[D]8010
Present scan time
*3
Accumulated instruction-execution
time from 0 step
(in units of 0.1 ms)
-
[D]8011
Minimum scan time
*3
Minimum value of scan time
(in units of 0.1 ms)
-
[D]8012
Maximum scan time
*3
Maximum value of scan time
(in units of 0.1 ms)
-
 D 8013
Second data
0 to 59 seconds
(for real time clock)
-
 D 8014
Minute data
0 to 59 minutes
(for real time clock)
-
 D 8015
Hour data
0 to 23 hours
(for real time clock)
-
 D 8016
Day data
1 to 31 days
(for real time clock)
-
 D 8017
Month data
1 to 12 months
(for real time clock)
-
 D 8018
Year data
2 digits of year data (0 to 99)
(for real time clock)
-
 D 8019
Day-of-the-week
data
0 (Sunday) to 6 (Saturday)
(for real time clock)
-
Present 
value
Type of memory
Protect switch
02H
EEPROM memory cassette
OFF
0AH
EEPROM memory cassette
ON
10H
Built-in memory in PLC
-
2 8
1 0 0
FX
3S
 Series
Version 1.00
8 0 6 1
8061 to 8068 (When M8004 is ON)
Number and name
Content of register
Correspond-
ing special 
device
Input filter
 D 8020
Input filter 
adjustment
Input filter value of X000 to X017
(Default: 10 ms)
-
[D]8021 to [D]8027 Not used
-
Index register Z0 and V0
[D]8028
Value of Z0 (Z) register
*4
-
[D]8029
Value of V0 (V) register
*4
-
Analog volume and constant scan
[D]8030
*5
Value of analog volume
VR1 (Integer from 0 to 255)
-
[D]8031
*5
Value of analog volume
VR2 (Integer from 0 to 255)
-
[D]8032 to [D]8038 Not used
-
 D 8039
Constant scan 
duration
Default: 0 ms (in 1 ms steps)
(Writes from system ROM at power
ON)
Can be overwritten by program
M8039
Stepladder
[D]8040
*6
ON state number 1
The smallest number out of active
state ranging from S0 to S255 is
stored in D8040 and the second-
smallest state number is stored in
D8041.
Active state numbers are then
sequentially stored in registers up to
D8047 (Max. 8 points).
M8047
[D]8041
*6
ON state number 2
[D]8042
*6
ON state number 3
[D]8043
*6
ON state number 4
[D]8044
*6
ON state number 5
[D]8045
*6
ON state number 6
[D]8046
*6
ON state number 7
[D]8047
*6
ON state number 8
[D]8048 to [D]8059 Not used
-