Справочник Пользователя для Avaya S8100
6
Hardware additions
Add Tie trunks
S8100 Installation and Upgrades
237
November 2003
Installation
1
Determine the port assignment of the trunk from Trunk Group form.
2
Install a DID Trunk circuit pack in assigned carrier slot (if an additional circuit pack is required).
3
Administer forms listed under “DID Trunk Group” in Administrator’s Guide for Avaya
Communication Manager (555-233-506).
Communication Manager (555-233-506).
Add Tie trunks
Requirements
Each tie trunk connects to 1 port of a 4-port Tie Trunk circuit pack or to an assortment of international Tie
Trunk circuit packs.
Trunk circuit packs.
Installation
1
Determine the port assignment of the trunk from Trunk Group form.
2
Install a Tie Trunk or an international Tie Trunk circuit pack in assigned carrier slot (if an
additional circuit pack is required).
additional circuit pack is required).
3
For customer-owned (not leased) tie-trunk facilities (such as campus environments), Tie Trunk
circuit packs provide signaling capabilities beyond those specified by the industry-wide E&M
standard. Use
circuit packs provide signaling capabilities beyond those specified by the industry-wide E&M
standard. Use
on page 238 to choose the preferred signaling
format, set switches on the circuit pack, and administer the port.
4
Administer forms listed under “Tie Trunk Group” in the Administrator’s Guide for Avaya
Communication Manager (555-233-506).
Communication Manager (555-233-506).
EXAMPLE:
Port number
1
A
07
01
Cabinet
Carrier
Slot
Circuit
(Port network)
(or compact modular
cabinet)
cabinet)
EXAMPLE:
Port number
3
A
02
01
Cabinet
Carrier
Slot
Circuit
(Port network)
(or compact modular
cabinet)
cabinet)