Справочник Пользователя для Polycom EF2280

Скачать
Страница из 20
B
UILDING
 Y
OUR
 S
YSTEM
 
WITH
 M
ULTIPLE
 V
OR
-
© Polycom, Inc.
5
Vortex
®
 
Applications and Presets Guide
an echo canceller reference on the EF Bus.  For each additional unit, assign the echo 
canceller reference to use the EF Bus Reference.
For systems with more than one room, you will need to use the W, X, Y, or Z sub-
busses to share the echo canceller reference in your additional rooms if the EF Bus 
Reference has already been assigned to the EF Bus.
A
UTOMIXER
 S
ETTINGS
 
FOR
 M
ULTIPLE
 V
ORTEXES
When using more than one Vortex in your room system, you have several possibilities 
for how you configure the automixer.  Each Vortex can operate as one of the follow-
ing:
One automixer, independent of other Vortexes linked to it
Two automixers, independent of other Vortexes linked to it
One large automixer, sharing automixer functions with other Vortexes linked to it
Two large automixers, sharing automixer functions with other Vortexes linked to 
it
Automixer and Bus 
Mixer Settings
To operate the Vortex in any of the above possibilites, two global parameters need to 
be changed: the A
UTOMIXER
 and the B
US
 M
IXER
 (see Figure 2).  The A
UTOMIXER
 
parameter chooses which automixer the input channel will be on (this is changed 
either on the A
UTOMIXER
 page in Conference Composer or on the M
ATRIX
 M
IXER
 
page).
The B
US
 M
IXER
 parameter is used to assign one of the two internal automixers to one 
of the eight EF Bus automixer groups.  For example, consider three Vortexes each of 
which has four microphones assigned to Automixer 1 and 4 microphones assigned to 
Automixer 2.  Now, if each of these Vortexes sets their Automixer 1 to have Bus 
Mixer 5 (the Bus Mixer is also referred to as the Bus ID), then the three automixers 
(one from each Vortex) will work as a single automixer containing 12 (3 x 4) micro-
phones.  Setting B
US
 M
IXER
 to 0 means that the automixer is not grouped on the EF 
Bus.
Operating as an 
Independent 
Automixer
To set the Vortex to operate as an independent automixer (or two independent mix-
ers), set the B
US
 M
IXER
 parameter to 0, or to a number that is different from any other 
automixer group currently in use on the EF Bus.
Figure 2. Vortex Automixer Global Parameters in Conference Composer Software