Справочник Пользователя для Sony PDW-1500

Скачать
Страница из 132
C
h
a
p
te
r 8  
 M
e
nu
s
100
8-3 Extended Menu
723
INPUT VIDEO BLANK
Switch blanking on or off for individual lines in the vertical blanking interval 
of an input video signal. The Y/C signal and odd/even fields are blanked 
simultaneously.
A signal with blanking carried out according to this setting is recorded.
Sub-item
0
ALL LINE
- - -: Specify the blanking for each line separately.
blnk: Regardless of the setting of other sub-items, blank all lines which 
can be specified in this menu item.
thru: Regardless of the setting of other sub-items, switch off blanking for 
all lines which can be specified in this menu item.
In 525(U)/
525(J)-line 
modes
12 ... 20
LINE 12 ... LINE 20
Specify blanking for lines 12 to 20.
blnk: Carry out blanking.
thru: Switch off blanking.
In 625-line 
mode
9 ... 22
LINE 9, 322 ... 
LINE 22, 335
Specify blanking for lines 9 to 22.
blnk: Carry out blanking.
thru: Switch off blanking.
726
H BLANKING WIDTH
Select the horizontal blanking width of the video output signal.
narow: Digital blanking (narrow)
wide: Analog blanking (wide)
When “wide” is selected, the horizontal blanking width complies with 
RS170A, and normally the blanking is widened and the image becomes 
narrower. It is recommended to select “narow” at the editing stage, then 
later, for broadcast transmission to select “wide,” to output a signal 
conforming to the standard. Note, however, that “narow” has to be always 
selected for SDI signals.
728
OUTPUT SCH PHASE
Set the subcarrier H phase.
–512 to 0 to 511
Menu items in the 700s, relating to video control
Item number Item name
Settings
Menu items in the 800s, relating to audio control
Item number Item name
Settings
802
DIGITAL AUDIO MUTING IN 
SHUTTLE MODE
Set the audio muting conditions during shuttle playback.
off: Not muted.
on: Muted.
807
AUDIO OUTPUT PHASE
Set the output timing of digital output signals (SDI, AES/EBU only), with 
80H as a reference position. Output timing is earlier for values smaller 
than 80H and later for values greater than 80H. (80H, 128 samples = 
approx. 2.7 ms, 80H, 1 sample = approx. 20 
µS
0 to 80 to FF: Values can be set in this range.
808
INTERNAL AUDIO SIGNAL 
GENERATOR
Select the operation of the internal audio test signal generator.
silnc: Silent signal.
1kHz: 1 kHz, -20 dB FS sine wave signal.
When you select SG as the audio input in the input selection section of 
the control panel, the audio test signal generated by the internal audio 
test signal generator is input.
815
AUDIO SAMPLING RATE 
CONVERTER
Select the mode of operation of the sampling rate converter for AES/
EBU input to channels 1 to 4.
off: No operation
on: Operate.