System Overview
3-15
TMRIN1
Timer Input 1 (input, synchronous, edge-sensitive)
This pin supplies a clock or control signal to the internal microcontroller 
timer 1. After internally synchronizing a Low-to-High transition on 
TMRIN1, the microcontroller increments the timer. TMRIN1 must be 
tied High if not being used.
TMROUT0
Timer Output 0 (output, synchronous)
This pin supplies the system with either a single pulse or a continuous 
waveform with a programmable duty cycle.
TMROUT1
Timer Output 1 (output, synchronous)
This pin supplies the system with either a single pulse or a continuous 
waveform with a programmable duty cycle. It can also be programmed 
as a watchdog timer.
TXD
Transmit Data (output, asynchronous)
This pin supplies asynchronous serial transmit data to the system from 
the internal UART of the microcontroller. 
UCS/ONCE1
Upper Memory Chip Select (output, synchronous)
ONCE Mode Request 1 (input, internal pullup)
UCS—This pin indicates to the system that a memory access is in 
progress to the upper memory block. The base address and size of the 
upper memory block are programmable up to 512 Kbyte. UCS is held 
High during a bus hold condition.
After power-on reset, UCS is asserted because the processor begins 
executing at FFFF0h and the default configuration for the UCS chip 
select is 64 Kbyte from F0000h to FFFFFh. See section 5.5.1.
ONCE1—During reset, this pin and ONCE0 indicate to the 
microcontroller the mode in which it should operate. ONCE0 and 
ONCE1 are sampled on the rising edge of RES. If both pins are asserted 
Low, the microcontroller enters ONCE mode; otherwise, it operates 
normally. In ONCE mode, all pins assume a high-impedance state and 
remain in that state until a subsequent reset occurs. To guarantee that 
the microcontroller does not inadvertently enter ONCE mode, ONCE1 
has a weak internal pullup resistor that is active only during a reset.
UZI/CLKSEL2
Upper Zero Indicate (output, synchronous)
UZI—This pin lets the designer determine whether an access to the 
interrupt vector table is in progress by ORing it with bits 15–10 of the 
address and data bus (AD15–AD10 on the Am186ER microcontroller 
and AO15–AO10 on the Am188ER microcontroller). UZI/CLKSEL2 is 
the logical AND of the inverted A19–A16 bits, and it asserts in the first 
period of a bus cycle and is held throughout the cycle.
UZI/CLKSEL2 is three-stated during bus holds and ONCE mode.
CLKSEL2—The clocking mode of the Am186ER and Am188ER 
microcontrollers is controlled by UZI/CLKSEL2 and S6/CLKSEL1 
during reset. Both CLKSEL2 and CLKSEL1 are held High during power-
on reset because of an internal pullup resistor. The default clocking 
mode—Times Four—is used if neither clock select is asserted Low 
during reset.