Locking the Front Panel (Executive Mode)
To prevent access by unauthorized users or accidental changes to the DSC settings, you 
can lock the front panel controls by placing the DSC in executive mode. In this mode, all 
front panel buttons are disabled and control is available only by SIS commands. 
To lock the front panel, do either of the following:
• 
Press and hold the front panel Menu and 
 buttons until the OSD displays the 
message Executive Mode Enabled (approximately 5 seconds). The message remains 
on the OSD approximately 2 seconds.
• 
Enter the 
Enable
 SIS command (see the 
To unlock the front panel, do either of the following:
• 
Press and hold the front panel Menu and 
 buttons again until the OSD displays 
the message 
Executive
 
Mode
 
Disabled
 (approximately 5 seconds). The message 
remains on the OSD approximately 2 seconds.
• 
Enter the 
Disable
Resetting
Resetting the unit causes various settings to revert to the defaults that were set at 
the factory. Resets can be performed from the front panel buttons, the OSD, or SIS 
commands. The following resets are available:
• 
Factory defaults: This reset clears all user-specified settings but retains the latest 
firmware version. You can perform this reset by:
• 
Selecting 
Factory
 
Reset
 from the 
Advanced
 submenu of the OSD (see the 
Advanced
 submenu on page 33) 
• 
Entering the 
Reset
 
all
 
device
 
settings
 
to
 
factory
 
default
 SIS command 
(see the 
 on page 60)
When the reset is complete, the message 
Factory
 
Reset
 is displayed on the OSD.
• 
Factory Firmware: This reset returns the unit to its factory default settings, including 
the original firmware with which it was shipped. All user settings are cleared. 
To perform this reset, press and hold the Enter button for 20 seconds while applying 
power to the unit. When the reset is completed, the message 
Firmware
 
Reset
 
appears on the OSD. 
NOTE:  The Firmware Reset and Factory Reset messages are displayed for 1 minute 
after the reset to allow time for the display device to sync with the DSC output.
DSC 3G-HD A and DSC HD-3G A • Operation
40