7000 Bus Converter User Manual (version 1.2,Feb/2003, 7PH-006-10)  --------------- 60 
3.3.4 Verifying the Installation: 
This section will guide you on how to verify if the I-7563 was properly 
installed. You will also need to determine the COM port assignment made 
by Windows for the USB to 3 Ports RS-485 Hub. 
 
Note:
 Before you plug in the I-7563 for the first time, make sure that you 
do not attach any serial device first to the converter. You must only plug in 
the I-7560 itself. 
 
To verify if the device is properly installed and determine the COM port 
assignment of the device: 
 
1. Click 
Start _ __ _ Control Panel _ __ _ System
. Inside System 
Properties, click on 
Device Manager
. Double-click on Ports (COM & 
LPT1). You should see the I-7563 USB-to-3 Ports RS485 Hub (COM3) 
device listing. This also means that Windows has assigned the device 
to COM3 port.