Справочник ПользователяСодержаниеContents5Figures9Tables13Preface15Safety Symbols Used in this Document16Contacting Allied Telesis17Chapter 119Overview19Introduction20AT-SBx8106 Chassis23Ethernet Line and Controller Cards Slots24Power Supply Slots25AT-SBx81GT24 Line Card27AT-SBx81GT40 Line Card28AT-SBx81GP24 PoE Line Card29AT-SBx81GS24a SFP Line Card30AT-SBx81XS6 SFP+ Line Card3110/100/1000Base-T Twisted Pair Ports32Connector Type32Speed32Duplex Mode32Maximum Distance33Cable Requirements33Automatic MDIX Detection34Port Pinouts34Power over Ethernet on the AT-SBx81GP24 Line Card35Powered Device Classes35Power Budgeting36PoE Wiring36Port LEDs on the Ethernet Line Cards38AT-SBx81GT24 Line Card38AT-SBx81GT40 Line Card39AT-SBx81GP24 Line Card41AT-SBx81GS24a Line Card42AT-SBx81XS6 Line Card43AT-SBx81CFC400 Controller Fabric Card44SYS Status LEDs45SBx STATUS LEDs47eco-friendly Button48Reset Button48NET MGMT Port49NET MGMT LED51Console (RS-232) Port51USB Port52AT-SBxPWRSYS1 AC Power Supply53LEDs53AT-SBxPWRPOE1 Power Supply55LEDs55AT-SBxPWRSYS1 DC Power Supply57LEDs58AT-SBxFAN06 Module59LED59Power Supply Interfaces (Opto-couplers)60LED60AlliedWare Plus Software Releases for the Hardware Components62Chapter 263Safety Precautions and Site Requirements63Reviewing Safety Precautions64Selecting a Site for the SwitchBlade x810668Installation Tools and Material70Chapter 371Installing the Chassis in an Equipment Rack71Required Tools and Material72Preparing the Equipment Rack73Unpacking the AT-SBx8106 Chassis76Removing the Rubber Feet78Adjusting the Equipment Rack Brackets80Installing the Chassis in the Equipment Rack82Removing the Shipping Brace86Installing the Chassis Grounding Lug87Chapter 489Installing the Power Supplies89Protecting Against Electrostatic Discharge (ESD)90Installing the AT-SBxPWRSYS1 AC System Power Supply91Installing the AT-SBxPWRPOE1 PoE Power Supply97Installing the AT-SBxPWRSYS1 DC Power Supply103Chapter 5109Installing the AT-SBx81CFC400 Controller and Ethernet Line Cards109Guidelines to Handling the Controller and Line Cards110Installing the AT-SBx81CFC400 Controller Fabric Card112Installing the Ethernet Line Cards118Installing the Blank Slot Covers122Chapter 6125Installing the Transceivers and Cabling the Ports125Cabling Guidelines for the Twisted Pair Ports on the AT-SBx81GT24, AT-SBx81GP24, and AT-SBx81GT40 Line Cards126Connecting Cables to the AT- SBx81GT40 Line Card127Guidelines to Installing SFP and SFP+ Transceivers129Installing SFP Transceivers in the AT-SBx81GS24a Line Card130Installing SFP+ Transceivers in the AT-SBx81XS6 Line Card134Installing AT-SP10TW Cables in the AT-SBx81XS6 Line Card138Cabling the NET MGMT Port on the AT-SBx81CFC400 Card141Chapter 7143Powering On the Chassis143Verifying the Installation144Powering On the AT-SBxPWRSYS1 AC Power Supply145Powering On the AT-SBxPWRPOE1 Power Supply148Powering On the AT-SBxPWRSYS1 DC System Power Supply151Choosing a Method for Attaching the Grounding Wire153Connecting the Grounding Wire with the Grounding Terminal153Connecting the Grounding Wire with Bare Wire156Choosing a Method for Attaching the Power Wires158Connecting the DC Power Wires with the Straight Terminals158Connecting the DC Power Wires with the Right Angle Terminals167Connecting Bare DC Power Wires173Monitoring the Initialization Process177Using the LEDs to Monitor the Initialization Process177Using the Console Port to Monitor the Initialization Process177Chapter 8181Verifying the Hardware Operations of the Chassis181Using the LEDs to Verify the Chassis182Using Local Management to Verify the Chassis184Starting a Local Management Session184Entering the AlliedWare Plus Operating System Commands185Chapter 9189Troubleshooting189AT-SBxPWRSYS1 and AT-SBxPWRPOE1 AC Power Supplies190AT-SBxPWRSYS1 DC Power Supply191Ethernet Line Cards193Twisted Pair Ports195Power Over Ethernet197Fiber Optic Transceivers199AT-SBx81CFC400 Controller Fabric Card200AT-SBxFAN06 Fan Module201Local (Out-of-Band) Management Session202Power Supply Interfaces (Opto-couplers)203Chapter 10205Replacing Modules205Replacing AT-SBxPWRSYS1 AC and AT-SBxPWRPOE1 Power Supplies206Replacing the AT-SBxPWRSYS1 DC Power Supply211Replacing Ethernet Line Cards222Replacing the AT-SBx81CFC400 Controller Fabric Card224Replacing the AT-SBxFAN06 Fan Module226Removing the AT-SBxFAN06 Fan Module226Installing a New AT-SBxFAN06 Fan Module229Appendix A233Technical Specifications233Physical Specifications233Environmental Specifications235Power Specifications236Safety and Electromagnetic Emissions Certifications238Port Pinouts239Размер: 4,0 МБСтраницы: 240Язык: EnglishПросмотреть
Справочник ПользователяСодержаниеContents5Figures9Tables13Preface15Safety Symbols Used in this Document16Contacting Allied Telesis17Chapter 119Overview19Introduction20AT-SBx8106 Chassis23Ethernet Line and Controller Cards Slots24Power Supply Slots25AT-SBx81GT24 Line Card27AT-SBx81GT40 Line Card28AT-SBx81GP24 PoE Line Card29AT-SBx81GS24a SFP Line Card30AT-SBx81XS6 SFP+ Line Card3110/100/1000Base-T Twisted Pair Ports32Connector Type32Speed32Duplex Mode32Maximum Distance33Cable Requirements33Automatic MDIX Detection34Port Pinouts34Power over Ethernet on the AT-SBx81GP24 Line Card35Powered Device Classes35Power Budgeting36PoE Wiring36Port LEDs on the Ethernet Line Cards38AT-SBx81GT24 Line Card38AT-SBx81GT40 Line Card39AT-SBx81GP24 Line Card41AT-SBx81GS24a Line Card42AT-SBx81XS6 Line Card43AT-SBx81CFC400 Controller Fabric Card44SYS Status LEDs45SBx STATUS LEDs47eco-friendly Button48Reset Button48NET MGMT Port49NET MGMT LED51Console (RS-232) Port51USB Port52AT-SBxPWRSYS1 AC Power Supply53LEDs53AT-SBxPWRPOE1 Power Supply55LEDs55AT-SBxPWRSYS1 DC Power Supply57LEDs58AT-SBxFAN06 Module59LED59Power Supply Interfaces (Opto-couplers)60LED60AlliedWare Plus Software Releases for the Hardware Components62Chapter 263Safety Precautions and Site Requirements63Reviewing Safety Precautions64Selecting a Site for the SwitchBlade x810668Installation Tools and Material70Chapter 371Installing the Chassis in an Equipment Rack71Required Tools and Material72Preparing the Equipment Rack73Unpacking the AT-SBx8106 Chassis76Removing the Rubber Feet78Adjusting the Equipment Rack Brackets80Installing the Chassis in the Equipment Rack82Removing the Shipping Brace86Installing the Chassis Grounding Lug87Chapter 489Installing the Power Supplies89Protecting Against Electrostatic Discharge (ESD)90Installing the AT-SBxPWRSYS1 AC System Power Supply91Installing the AT-SBxPWRPOE1 PoE Power Supply97Installing the AT-SBxPWRSYS1 DC Power Supply103Chapter 5109Installing the AT-SBx81CFC400 Controller and Ethernet Line Cards109Guidelines to Handling the Controller and Line Cards110Installing the AT-SBx81CFC400 Controller Fabric Card112Installing the Ethernet Line Cards118Installing the Blank Slot Covers122Chapter 6125Installing the Transceivers and Cabling the Ports125Cabling Guidelines for the Twisted Pair Ports on the AT-SBx81GT24, AT-SBx81GP24, and AT-SBx81GT40 Line Cards126Connecting Cables to the AT- SBx81GT40 Line Card127Guidelines to Installing SFP and SFP+ Transceivers129Installing SFP Transceivers in the AT-SBx81GS24a Line Card130Installing SFP+ Transceivers in the AT-SBx81XS6 Line Card134Installing AT-SP10TW Cables in the AT-SBx81XS6 Line Card138Cabling the NET MGMT Port on the AT-SBx81CFC400 Card141Chapter 7143Powering On the Chassis143Verifying the Installation144Powering On the AT-SBxPWRSYS1 AC Power Supply145Powering On the AT-SBxPWRPOE1 Power Supply148Powering On the AT-SBxPWRSYS1 DC System Power Supply151Choosing a Method for Attaching the Grounding Wire153Connecting the Grounding Wire with the Grounding Terminal153Connecting the Grounding Wire with Bare Wire156Choosing a Method for Attaching the Power Wires158Connecting the DC Power Wires with the Straight Terminals158Connecting the DC Power Wires with the Right Angle Terminals167Connecting Bare DC Power Wires173Monitoring the Initialization Process177Using the LEDs to Monitor the Initialization Process177Using the Console Port to Monitor the Initialization Process177Chapter 8181Verifying the Hardware Operations of the Chassis181Using the LEDs to Verify the Chassis182Using Local Management to Verify the Chassis184Starting a Local Management Session184Entering the AlliedWare Plus Operating System Commands185Chapter 9189Troubleshooting189AT-SBxPWRSYS1 and AT-SBxPWRPOE1 AC Power Supplies190AT-SBxPWRSYS1 DC Power Supply191Ethernet Line Cards193Twisted Pair Ports195Power Over Ethernet197Fiber Optic Transceivers199AT-SBx81CFC400 Controller Fabric Card200AT-SBxFAN06 Fan Module201Local (Out-of-Band) Management Session202Power Supply Interfaces (Opto-couplers)203Chapter 10205Replacing Modules205Replacing AT-SBxPWRSYS1 AC and AT-SBxPWRPOE1 Power Supplies206Replacing the AT-SBxPWRSYS1 DC Power Supply211Replacing Ethernet Line Cards222Replacing the AT-SBx81CFC400 Controller Fabric Card224Replacing the AT-SBxFAN06 Fan Module226Removing the AT-SBxFAN06 Fan Module226Installing a New AT-SBxFAN06 Fan Module229Appendix A233Technical Specifications233Physical Specifications233Environmental Specifications235Power Specifications236Safety and Electromagnetic Emissions Certifications238Port Pinouts239Размер: 4,1 МБСтраницы: 240Язык: EnglishПросмотреть