Техническая Спецификация (EVL170W-FTV)СодержаниеFigure 1. EVL170W-FTV: 170 W demonstration board11 Main characteristics and circuit description6Figure 2. Electrical diagram82 Efficiency measurement9Table 1. Overall efficiency measured at different AC input voltages9Figure 3. Overall efficiency vs. output power10Figure 4. Average efficiency acc. ES-210Figure 5. Standby supply efficiency vs. output power10Figure 6. Standby supply efficiency vs. light load output power103 Harmonic content measurement11Figure 7. EN61000-3-2 compliance at 230 Vac - 50 Hz, full load11Figure 8. JEITA-MITI compliance at 100 Vac - 50 Hz, full load11Figure 9. EN61000-3-2 compliance at 230 Vac - 50 Hz, 75 W11Figure 10. JEITA-MITI compliance at 100 Vac - 50 Hz, 75 W11Figure 11. Input voltage and current at 100 Vac, full load12Figure 12. Input voltage and current at 230 Vac, full load124 Functional check13Figure 13. Standby supply waveforms at 115 Vac - 60 Hz, full load13Figure 14. Standby supply waveforms at 230 Vac - 50 Hz, full load13Figure 15. Standby supply waveforms at 400 Vdc, full load14Figure 16. Standby supply output rectifiers PIV at 400 Vdc, full load14Figure 17. Standby supply 5 V ripple at 115 Vac - 60 Hz, full load14Figure 18. Standby supply startup at 115 Vac - 60 Hz, full load14Figure 19. Standby supply burst mode operation at 230 Vac - 50 Hz - 10 mA load15Figure 20. Standby supply burst mode operation at 230 Vac - 50 Hz - 10 mA load-detail15Figure 21. Standby supply OVP at 115 Vac - 60 Hz, full load15Figure 22. Standby supply OVP at 230 Vac - 50 Hz - 0.5 A15Figure 23. Standby supply OVP at 115 Vac - 60 Hz - PFC on - 1 A16Figure 24. Standby supply OVP at 115 Vac - 60 Hz - PFC on - 1 A16Figure 25. Standby supply output short-circuit at 230 Vac - 50 Hz, full load16Figure 26. Standby supply output short-circuit at 230 Vac - 50 Hz, full load - detail16Figure 27. Standby supply dynamic load at 115 Vac - 60 Hz - PFC off17Figure 28. Standby supply dynamic load at 115 Vac - 60 Hz - PFC on17Figure 29. PFC Vds and inductor current at 115 Vac - 60 Hz, full load18Figure 30. PFC Vds and inductor current at 115 Vac - 60 Hz, full load - detail18Figure 31. PFC Vds and inductor current at 230 Vac - 50 Hz, full load19Figure 32. PFC Vds and inductor current at 230 Vac - 50 Hz, full load - detail19Figure 33. L6564 signals-1 at 115 Vac - 60 Hz, full load19Figure 34. L6564 signals-2 at 115 Vac - 60 Hz, full load19Figure 35. PFC signals-1 at 115 Vac - 60 Hz, full load20Figure 36. PFC signals-2 at 115 Vac - 60 Hz, full load20Figure 37. Resonant stage waveforms at 115 V - 60 Hz, full load21Figure 38. Resonant stage waveforms at 115 V - 60 Hz, full load21Figure 39. Output rectifiers PIV waveforms22Figure 40. No load operation at 115 Vac - 60 Hz22Figure 41. No load operation at 115 Vac - 60 Hz - L6599A signals22Figure 42. 12 V - 2 A; 24 V 0 ÷ 6 A transition at 115 Vac - 60 Hz23Figure 43. 24 V - 6 A; 12 V 0 ÷ 2 A transition at 115 Vac - 60 Hz23Figure 44. 12 V - 2 A; 24 V 0 ÷ 6 A - 300 Hz transition at 115 Vac - 60 Hz24Figure 45. 24 V - 6 A; 12 V 1 ÷ 2 A - 300 Hz transition at 115 Vac - 60 Hz24Figure 46. 12 V short-circuit at full load and 115 Vac - 60 Hz25Figure 47. 12 V short-circuit at full load and 115 Vac - 60 Hz - detail25Figure 48. 24 V short-circuit at full load and 115 Vac - 60 Hz25Figure 49. 24 V short-circuit at full load and 115 Vac - 60 Hz - detail25Figure 50. Startup by on-off signal at full load and 115 Vac - 60 Hz26Figure 51. Startup by on-off signal at full load and 115 Vac - 60 Hz - L6599A signals26Figure 52. Startup by on/off signal at full load and 115 Vac - 60 Hz O/P voltage rising27Figure 53. Turn-off at full load and 115 Vac - 60 Hz by on/off signal27Figure 54. OVP at full load and 115 Vac - 60 Hz on 12 V - 24 V27Figure 55. OVP at full load and 115 Vac - 60 Hz on 12 V - 24 V - outputs detail27Figure 56. Half cycle mains dip at full load and 115 Vac - 60 Hz28Figure 57. Full cycle mains dip at full load and 115 Vac - 60 Hz285 Conducted emission pre-compliance test29Figure 58. CE peak measurement at 115 V - 60 Hz and full load - phase wire29Figure 59. CE peak measurement at 115 V - 60 Hz and full load - neutral wire29Figure 60. CE peak measurement at 230 V - 50 Hz and full load - phase wire30Figure 61. CE peak measurement at 230 V - 50 Hz and full load - neutral wire306 Bill of materials31Table 2. Bill of materials317 PFC coil specifications39Figure 62. PFC coil electrical diagram39Table 3. PFC coil winding data39Figure 63. PFC coil mechanical aspect408 Resonant power transformer specifications41Figure 64. Transformer overall drawing41Table 4. Resonant transformer winding data41Figure 65. Transformer electrical diagram429 Auxiliary flyback transformer specifications43Table 5. DC output voltage and load43Figure 66. Transformer construction44Table 6. Standby transformer winding data44Figure 67. Mechanical aspect and pin numbering44Figure 68. Mechanical aspect and pin numbering4510 Revision history46Table 7. Document revision history46Размер: 2,0 МБСтраницы: 47Язык: EnglishПросмотреть