Справочник ПользователяСодержаниеQuikBridge Node repeater1Product Summary1Tools and Accessories Needed1Overview of Repeater Components Operation2LED Indications2Installation Overview3Installation using a PC31. Mount the repeater board in the enclosure.32. Assemble the antenna shrouds and snap into place.43. Connect the AC transformer leads and power the board.44. Connect the USB cable from the PC to the repeater board.45. Using the PC software, perform the initial configuration of the repeater.46. Use the PC software to enter enrollment mode. Enroll the desired sensors into the repeater.47. Mount the repeater in its final location.48. Connect the AC transformer leads and power the board.49. Connect the battery (if applicable).410. Install the tamper switch.411. Mount the enrolled sensors in their final locations.412. Test the communication between the repeater and the base station receiver.413. Test the communication between the enrolled sensors and the repeater.4Installation Using the On-board DIP Switches41. Mount the repeater board in the enclosure.42. Assemble the antenna shrouds and snap into place.43. Connect the AC transformer leads and power the board.44. Connect the USB cable from the PC to the repeater board.45. Using the PC software, perform the initial configuration of the repeater.46. Mount the repeater in its final location.47. Connect the AC transformer leads and power the board.48. Connect the battery (if applicable).49. Install the tamper switch.410. Use the DIP switches to enter Enrollment Mode. Enroll the desired sensors into411. the repeater.412. Set the DIP switches back to Normal Mode.413. Mount the enrolled sensors in their final locations.414. Test the communication between the repeater and the base station receiver.415. Test the communication between the enrolled sensors and the repeater.4Mounting the Repeater4Mounting Guidelines4Connecting the Antenna Shrouds to the Repeater4Installing the Tamper Switch5Powering the Repeater5Initial Configuration5Enrolling Sensors into the Repeater51. Put the repeater in enrollment mode via the PC or the DIP switches.52. Send an enrollment packet from the desired sensor. The method for sending the enroll ment packet varies depending on the type of sensor; see the installation instructions for each sensor for more information.53. Verify that the enrollment packet was received by the repeater and that the sensor was enrolled, either through the PC interface or via the red LED.54. Repeat until all sensors have been enrolled.5Deleting Sensors from the Repeater5PC Method5DIP Switch Method51. Put the repeater in individual delete mode via the DIP switches.52. Send an enrollment packet from the desired sensor (the “enrollment” packet is used for both deletion as well as enrollment). The method for sending the enrollment packet varies depending on the type of sensor; see the installation instruct...53. Verify that the packet was received by the repeater and that the sensor was deleted by watching for a long flash on the red LED.54. Repeat for each sensor to be deleted.61. Put the repeater in delete all mode via the DIP switches.62. Verify that the red LED is blinking.63. Press and release the tamper switch.64. Verify one long flash on the red LED, signaling successful deletion of all sensors.6Testing the Repeater Transmitter6Testing the Repeater Receiver61. Take the cover off this repeater so you can observe the LED.62. Cause each sensor to transmit and count packets received.63. If any one of the sensors fails this test, relocate the repeater and repeat both the Repeater Transmitter6Specifications6Notices7Document Number: 466-20XX Rev. A July 20031PRELIMINARY 7/24/031Размер: 108,2 КБСтраницы: 8Язык: EnglishПросмотреть