Desa Tech CSPINT 用户手册

下载
页码 24
www.desatech.com
111487-01D
18
 WARNING: If you smell gas
•  Shut off gas supply.
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your 
building.
•  Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.
IMPORTANT:
 Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, 
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These 
fumes may mix with combustion air and create odors. These odors will disappear over time.
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Metal expanding while heating 
or contracting while cooling
1. Heater burning vapors from 
paint,  hair  spray,  glues, 
cleaners,  chemicals,  new 
carpet,  etc.  (See  IMPOR-
TANT 
statement above)
2. Gas  leak.  See  Warning 
statement  at  top  of 
page
1. Not  enough  fresh  air  is 
available
2. Low line pressure
3. ODS/pilot  is  partially 
clogged
1. Gas  leak.  See  Warning 
statement  at  top  of 
page
2. Control valve defective
1. Foreign matter between con-
trol valve and burner
2. Gas  leak.  See  Warning 
statement  at  top  of 
page
OBSERVED PROBLEM
Heater produces a clicking/tick-
ing noise just after burner is lit 
or shut off
Heater  produces  unwanted 
odors
Heater  shuts  off  in  use  (ODS 
operates)
Gas odor even when control knob 
is in OFF position
Gas odor during combustion
REMEDY
1. This is common with most heat-
ers. If noise is excessive, contact 
qualified service person
1. Open  window  and  ventilate 
room. Stop using odor caus-
ing products while heater is 
running
2. Locate  and  correct  all  leaks 
(see  Checking  Gas  Connec-
tions, page 11)
1. Open window and/or door for 
ventilation
2. Contact local natural or pro-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning 
and Maintenance, page 14)
1. Locate  and  correct  all  leaks 
(see  Checking  Gas  Connec-
tions, page 11)
2. Replace control valve
1. Take  apart  gas  tubing  and 
remove foreign matter
2. Locate  and  correct  all  leaks 
(see  Checking  Gas  Connec-
tions, page 11)