Patton electronic 1080ARC 用户手册

下载
页码 40
 
13
 
3.4  CONFIGURATION SWITCH SET S3
 
The DIP switches on S3 set the antistream control, local loopback 
enable, remote loopback enable and receive (input) impedance levels for 
the Model 1080ARC.  The default settings are summarized in Table 12 
and Table 13.
 
Table 12: 
 
Summary of DIP switch default settings for S3
 
Position
Function
Factory Default
 
S3-1
Input Impedance
On
200 Ohms
S3-2
Input Impedance
Off
200 Ohms
S3-3
Not yet assigned
n/a
S3-4
Mode Selection
On 
Point to Point
S3-5
Local Loopback
Off
Disabled
S3-6
Remote Loopback
Off
Disabled
S3-7
Antistream Control
Off
Disabled
S3-8
Antistream Control
Off
Disabled
 
Table 13: 
 
Selection Table for S3-1, S3-2
 
Data Rates (kbps)
Cable
gauge 
1.2
1.8
2.4
3.6
4.8
7.2
9.6
14.4
19.2
28.8
38.4
57.6
 
19
320
320
200
200
200
200
200
130
130
130
130
130
22
320
320
320
200
200
200
200
200
130
130
130
130
24
320
320
320
320
200
200
200
200
200
130
130
130
26
320
320
320
320
320
200
200
200
200
200
130
130