Hitachi HD64F3694G 用户手册
![Hitachi](https://files.manualsbrain.com/attachments/318a30c9d46cae1a03ff29c8e1a8ce7b06c25f29/common/fit/150/50/c3659964771301ddbc1d53d08b2407adc4af72464bc0f65ffa4212552d47/brand_logo.png)
Rev. 1.0, 07/01, page 171 of 372
Figure 12-16 shows the output compare timing.
GRA to GRD
TCNT
TCNT input
clock
clock
φ
N
N
N+1
Compare
match signal
match signal
FTIOA to FTIOD
Figure 12-16 Output Compare Output Timing
12.5.3
Input Capture Timing
Input capture on the rising edge, falling edge, or both edges can be selected through settings in
TIOR0 and TIOR1. Figure 12-17 shows the timing when the falling edge is selected. The pulse
width of the input capture signal must be at least two system clock (
TIOR0 and TIOR1. Figure 12-17 shows the timing when the falling edge is selected. The pulse
width of the input capture signal must be at least two system clock (
φ
) cycles; shorter pulses will
not be detected correctly.
TCNT
Input capture
input
input
ø
N–1
N
N+1
N+2
N
GRA to GRD
Input capture
signal
signal
Figure 12-17 Input Capture Input Signal Timing