3/8" Cable Connector
*
*
NOTE: Strain relief cable connector            
must be installed. Not Included.
A
B
C
Extra Screws
x2
I
2
3
 DISCONNECT 
ELECTRIC 
POWER SUPPLY 
AND LOCK OUT 
SERVICE PANEL 
BEFORE 
SERVICING UNIT
  W A R N I N G
TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:
1.  For general ventilating use only. Do not use for ventilat-
ing hazardous or explosive materials.
2.  To avoid motor bearing damage and noisy/unbalanced 
impellers, keep drywall spray, construction dust, etc. off 
power unit.
3.  DO NOT install this product in a wall. This product is 
designed for installation in ceilings up to a 12/12 pitch 
(45 degrees). Ductwork must point upward.
4.  Please read specification label on product for further 
information and requirements.
PREVENTATIVE MAINTENANCE
A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.
TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel 
wool pads or scouring powders.
TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor 
plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a 
screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
MAINTENANCE
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual 
noises, replace the motor with the exact service motor. You should replace the impeller at the same time.
 
C A U T I O N
  W A R N I N G
1.  Use this unit only in a manner intended by the manufacturer. 
If you have questions, contact the manufacturer at the phone 
number or address listed in the warranty.
2.  Before installing, servicing, or cleaning the unit,  
disconnect the power by turning off the circuit breakers to 
the outlet box and associated wall switch location. If you 
cannot lock the circuit breakers in the off position, securely 
attach a prominent warning device, such as a tag, to the 
service panel.
 
3.  Installation work and electrical wiring must be done by 
qualified person(s) in accordance with all applicable codes 
and standards, including fire-rated construction codes and 
standards.
4.  Sufficient air is needed for proper combustion and exhaust-
ing of gasses through the flue (chimney) of fuel burning 
equipment to prevent backdrafting. Follow the heating  
equipment manufacturer’s guideline and safety standards, 
   such as those published by the National Fire Prevention 
Association (NFPA), and the American Society for Heating, 
Refrigeration and Air-Conditioning Engineers (ASHRAE), and 
the local code authorities.
  5.  When cutting or drilling into wall(s) or ceiling, do not  
damage electrical wiring or other hidden utilities.
  6.  Ducted fans must always be vented to the outdoors. Keep 
ducting as short and as straight as possible.
  7.  Acceptable for use over a bathtub or shower when  
connected to a GFCI protected branch circuit.
  8. Install fan at least 5 feet (1.52 m) above the floor.
  9.  Never place a switch where it can be reached from a tub  
or shower.
10. This unit must be grounded.
OFF
30
OF
F
30
OF
F
20
30
OF
F
30
OFF
30
2
1
Turn off the power source.
Tools Needed.
Estimated assembly time: 30 to 60 minutes
 
Before Installation
Check all the parts. 
If damaged, call
 
1-888-830-1326 
for replacements.
Included.
2
E
I
Loosen screws.
 
41721-01  12/25/2004
 
41721-01  12/25/2004 
NOTE: Remove all packing materials before installation.