Toshiba SL-5300 Series 用户手册

下载
页码 224
6. LEVEL ADJUSTMENT
 
EO1-31009 
 
6. LEVEL ADJUSTMENT 
6- 1 
6. LEVEL ADJUSTMENT 
 
 
 
 
 
For correct weighing operations, be sure to level the scale.  Turn the four adjustable legs so that the 
bubble in the level gauge is positioned at the center.  
 
NOTES:  
1.  Make sure that the scale is leveled before the business hour starts.  
2.  To prevent the level adjustment from being changed unconsciously and the power cord from being 
squashed, fixing the adjustable legs with the enclosed nuts is recommended. 
 
 
 
 
 
 
 
  When the bubble is positioned rightward.  
 
Turn the left adjustable legs clockwise, or 
turn the right adjustable legs 
counterclockwise.  
 
 
 
 
 
 
 
 
 
 
 
 
  When the bubble is positioned backward.  
 
Turn the front adjustable legs clockwise, or 
turn the rear adjustable legs 
counterclockwise. 
 
 
 
 
 
 
 
 
  
 
 
 
 
Level Gauge 
Left Adjustable  
Legs 
WARNING! 
Care must be taken not to squash the power cord by the scale when adjusting the level, as this may 
cause electric shock or fire.  
Right Adjustable Legs 
Front Adjustable Legs 
Rear Adjustable Leg 
Rear Adjustable Leg 
Nut 
Adjustable Leg 
  When the bubble is positioned leftward
 
Turn the right adjustable legs clockwise, or turn
the left adjustable legs counterclockwise.  
••••
  When the bubble is positioned frontward. 
 
Turn the rear adjustable legs clockwise, or turn 
the front adjustable legs counterclockwise.