MC55 AT Command Set  
16.13 AT^SNFO
s
m
obile
MC55_ATC_V01.05
Page 411 of 469
2/10/04
Confidential / Released
 
Formula to calculate the value of the 5 volume steps selectable with parameter 
:
Attenuation = 20 log * (2 * outCalibrate[n] / 32768)
0...32767
Volume steps 0 - 4, each defined with outCalibrate[n]
0...[4]
Multiplication factor for the sidetone gain.
Formula to calculate how much of the original microphone signal is added to the earpiece signal:
Sidetone gain in dB = 20 * log (sideTone / 32768).
0...32767
Notes
• The write command works only in audio modes 2 to 6.
• The read and write commands refer to the active audio mode.
 specifies the amount of volume of eac
. The range of eac
 is up to 65535, but will be suppressed to 32767. A value above 
= 65535 will cause
an error.
• The range of 
 is up to 65535, but will be suppressed to 32767. A value above 
65535 will cause an error.
• Any change to 
 takes effect in audio modes 2 to 6. That is, when you change 
then select another mode with 
, the same step will be applied. Nevertheless, the sound quality and
the amount of volume are not necessarily the same, since all remaining audio parameters can use different
values in either mode. 
• Audio mode 1 is fixed to 
=4. In this mode, any attempt to change 
 or other parameters
returns an error.
• The value of 
 is stored non-volatile when the ME is powered down with 
 or reset with
=x,1. Any other parameters changed with 
 need to be saved with 
 for use after
restart. See also 
 for details on restoring factory defaults.
• The values of 
 can also be changed with 
 and 
• CAUTION! When you adjust audio parameters avoid exceeding the maximum allowed level. Bear in mind that
exposure to excessive levels of noise can cause physical damage to users!
<outCalibrate>
(num)(^SNFW)
<outStep>
(num)
<sideTone>
(num)(^SNFW)