[1]
Audio mode 1: Standard mode optimized for the reference handset, that can
be connected to the analog interface 1 (see your "Hardware Interface Descrip-
tion" for information on this handset.) To adjust the volume use the knob of the
reference handset. In audio mode 4, this handset can be used with user
defined parameters.
Note: The default parameters are determined for type approval and are not
adjustable with AT commands. 
 restores 
 1. 
2
Audio mode 2: Customer specific mode for a basic handsfree device (Siemens
Car Kit Portable).
Analog interface 2 is assumed as default.
3
Audio mode 3: Customer specific mode for a mono-headset.
Analog interface 2 is assumed as default. 
4
Audio mode 4: Customer specific mode for a user handset.
Analog interface 1 is assumed as default. 
5
Audio mode 5: Customer specific mode. 
Analog interface 1 is assumed as default. 
6
Audio mode 6: Customer specific mode.
Analog interface 2 is assumed as default. 
Notes
• The write command can be used during a voice call to switch back and forth between different modes. This
allows the user, for example, to switch handsfree operation on and off.
• Users should be aware that 
 is a global setting. This means, when another audio mode is selected
during a call, the value of 
 does not change. This is also true for mute operation which can be set
with 
 or 
: If the microphone is muted and the user selects another audio mode during the
call, then the microphone remains muted until explicitly changed. Exception: In audio mode 1 
is fix.