December 31, 2007
The following table shows the +COLP parameters.
Example
AT+COLP=0
OK
AT+COLP=2
+CME ERROR: Numeric parameter out of bounds
Table 3-36: +COLP Parameters
<Parameter>
Description
<n>
Sets/displays the result code presentation status of the G24.
0
0
Disable (default)
1
Enable
<m>
Displays the subscriber’s COLP service status in the network.
0
0
COLP not provisioned
1
COLP provisioned
2
Unknown (for example, no network, and so on)
<number>
Sets the phone number, using the format specified by <type>.
<type>
Sets the address octet type in integer format (refer to GSM 04.08 [8] subclause
10.5.4.7).
129
10.5.4.7).
129
Unknown
145
International (used when dialing string includes "+" international access code
character)
<subaddr>
Sets the subaddress, using the format specified by <satype>.
<satype>
Sets the address octet type in integer format (refer to GSM 04.08 [8] subclause
10.5.4.8).
10.5.4.8).
<alpha>
An optional, string-type, alphanumeric representation of <number> corresponding to
the entry found in the phonebook. The character set is defined by +CSCS (