Motorola G24 用户手册

下载
页码 642
Chapter 3:  AT Commands Reference
 December  31, 2007
AT Commands Reference Manual
3-227
+MVREF, Motorola Voltage Reference
This command defines the Vref regulator's configuration. Pin 27 is used as indicator signal that 
reflects the configuration of Vref regulator. This command is a basic command. The command is 
also sensitive to ATS24 command.
The following table shows the +MVREF parameters.
Example
AT+MVREF=?
+MVREF:(0-2)
OK
AT+MVREF=1
OK
AT+MVREF?
+MVREF: 1
Command 
Type
Syntax
Response/Action
Remarks
Set
+MVREF=<control>
OK
or:
+CME ERROR: <err>
The Set command is used for setting 
the behavior of Vref regulator.
Read
+MVREF?
+MVREF: <control>
OK
or:
+CME ERROR: <err>
The Read command returns the current 
behavior <control> value.
Test
+MVREF=?
+MVREF: (0-2)
OK
The Test command returns the possible 
values' range.
Table 3-146: +MVREF Parameters
<Parameter>
Description
<control>
0
OFF mode.
1
ON mode.
2
STANDBY mode (default).
For additional information about pin 27’s signals, 
.
Table 3-147: +MVREF Signals Values
Mode
Voltage
Current
0
0V
0A
1
2.75V
50mA
2
2.75V
ATS24 is 0: 50mA
ATS24 is not 0: The current is 
changed alternately from 50mA to 
2mA and back to 50mA.