Motorola G24 用户手册

下载
页码 642
Chapter 3:  AT Commands Reference
 December  31, 2007
AT Commands Reference Manual
3-289
The following table shows the +MSCTS parameters.
Example
AT+MSCTS = ? 
+MSCTS: (0-1)
OK
AT+MSCTS? 
+MSCTS: 0
OK
AT+MSCTS = 1
OK
ATS102?
1
OK
Note:
This means that by waking up, the CTS line will stay OFF and it can be activated by the 
Wakeup IN Line interrupt only.
Error Handling Commands
+CMEE, Report Mobile Equipment Error
The Set command disables or enables the use of result code +CME ERROR: <err> as an 
indication of an error relating to the functionality of the G24. When enabled, G24-related errors 
cause a +CME ERROR: <err> final result code instead of the regular ERROR final result code. 
Usually, ERROR is returned when the error is related to syntax, invalid parameters or terminal 
functionality.
For all Accessory AT commands besides SMS commands, the +CMEE set command disables or 
enables the use of result code +CME ERROR: <err> as an indication of an error relating to the 
functionality of the G24. When enabled, G24 related errors cause a +CME ERROR: <err> final 
result code instead of the regular ERROR result code.
For all SMS AT commands that are derived from GSM 07.05, the +CMEE Set command disables 
or enables the use of result code +CMS ERROR: <err> as an indication of an error relating to the 
functionality of the G24. When enabled, G24-related errors cause a +CMS ERROR: <err> final 
result code instead of the regular ERROR final result.
Table 3-192: +MSCTS Parameters
<Parameter>
Description
 <control>
0
In Normal Mode: The CTS is used for Flow Control 
In Sleep mode: The CTS is inactive.
1
Wakeup In line is Active: The CTS is used for Flow Control. 
Wakeup In line is Inactive: The CTS is inactive. 
The default value is 0.