Motorola MC50 用户手册

下载
页码 98
Accessories 3 - 13
USB Connection
The CAM can connect to and communicate with a USB device, such as a host computer, through its data port. 
Refer to the MC50 Integrator Guide for the host computer communication setup procedure.
To connect the CAM to a USB device, connect one end of the data cable to the data port on the CAM and the 
other end to the USB port on the device.
 Figure 3-13    
CAM USB Connection
Universal Battery Charger (UBC) Adapter
This section describes how to use the UBC adapter to charge a spare battery.
Use the UBC with a power supply as a standalone spare battery charger, or with the four station UBC2000 to 
simultaneously charge up to four spare batteries. For additional information about the UBC2000, see the UBC 
2000 Universal Battery Charger Product Guide
 (p/n 70-33188-xx).
To Device
USB Port
Data Port
NOTE
Use only a Motorola-approved power supply (p/n 50-14000-147) output rated 5.4 VDC and minimum 3A. 
The power supply is certified to EN60950 with SELV outputs. Use of alternative power supply will 
invalidate any approval given to this device and may be dangerous.
HINWEIS Benutzen Sie nur eine von Motorola genehmigte Stromversorgung (Teilenr. 50-14000-147) mit einer 
Ausgangsleistung von 5.4 V (Gleichstrom) und mindestens 3A. Die Stromversorgung ist nach EN60950 
für die Verwendung in SELV-Stromkreisen zertifiziert. Bei Verwendung eines anderen Netzteils werden 
alle für das Gerät gewährten Genehmigungen außer Kraft gesetzt, und der Betrieb kann gefährlich sein.