Display 20 – Charging state 
 
        **************         ############## 
        * aaa  bbbbb *         #BatVol ChMod# 
        * Tccc  dddd *         #Btemp ChTime# 
        * Ceee  Wfff *         #ChrgVol Pwm # 
        * gggg  hhhh *         # Btyp  BFDC # 
        **************         ############## 
 
 
aaa 
Battery voltage in decimal, range is 0.00 - 9.99 V, decimal point is not 
shown; e.g. 7.19 V is shown as 719 on the display 
 
bbbbb 
Charging mode 5 digit symbol: 
xxxxx : Charger not connected or charging disabled.  
BatCk : Battery testing is going. 
BSIFa : Charging off because of battery BSI measurement failed. 
CelBr : Charging off because one or more cells broken inside 
battery. 
ChaCk : EM is checking charger. 
Charg : Charging. 
ColdC : Cold charging. 
ColdM : Battery cold and maintenance going. 
CurFa : Charging off because charger current measurement failed. 
DisCh : Battery discharging going. 
F_Che : Fast charging checks. 
Faile : Failure. 
FastC : Fast charging going. 
FullM : Battery full and maintenance going. 
HotM  : Battery hot and maintenance going. 
I_Che : Init checks. 
InitC : EM charging is being initialized. 
L_Che : Li charging checks. 
LiAFu : PWM level is below the battery full limit. 
LiDCH : Li-ion DCH charging. 
LiFul : PWM has been below the battey full limit for a certain time 
that is specified for full battery. 
LiHot : Li-ion hot charging. 
LithC : Charging of Lithium-ion battery. 
LiTxO : TX on and Li charging going. 
LNFTx : TX on, Li charging going and battery is not full anymore. 
M_Che : Maintenace charging checks. 
MaBFD : Maintenace BFD charging. 
Maint : Maintenance charging. 
TmpFa : Charging off because of battery NTC measurement failed. 
TxNoF : TX on, Ni charging going and battery is not full anymore. 
TxOnC : TX on and Ni charging going. 
VolFa : Charging off because charger voltage measurement failed. 
 
ccc 
Battery temperature in centigrade, from -30 to +90. 
ddd 
Charging time. Format is HMM. Timer is automatically reset and started when 
charger is connected and stopped when battery is full or charger is 
disconnected. 
eee 
Charger voltage in decimal, range is 0.0 - 18.7 V, decimal point is not shown. 
fff 
Charge control output, decimal, range is 000 - 255. 
gggg 
Lithium battery type (BSI value multiplied by 4), or NiMH battery size. 
hhhh 
Battery full delay counter. When battery is getting full and charging current 
is less than predefined limit, this timer will be started. If timer reaches 0, 