Panasonic 700 用户指南

下载
页码 394
Appendix B. CPC-AII/B 8.0 Feature Update
Section 700-Operation
Page B-20
DBS Manual - Revised April 2000
DBS-2.3/9.2-700
Programming
See Section 400 - Programming (Appendix D) for more detailed 
programming information.
Operation
The 44-Series EM/24 operates the same as previous models.
Modification to Toll Restriction Service
Description
The program address for TRS Operator Access (FF7 1# 18#...) has been 
modified to allow an extension to dial “0+NXX” phone numbers, even if 
“0-only” dialing is denied.
Four settings are possible. 
Programming
See Section 400 - Programming (Appendix D) for more detailed 
programming information.
Notes
• The Operator Access address applies only to DBS systems using the 
(1995) NANP dialing plan (FF7 1# 17# 1#), and to TRS types 2-6 (TRS 
types 0 and 1 do not allow outbound dialing; TRS type 7 allows all 
dialing).
• If “0-only”, “00-only”, “10XXX0-only”, or “101XXXX0-only” calls 
are restricted (settings 0 or 2), the system will wait 6 seconds before 
automatically disconnecting the call. However, if the user dials 
additional digits within 6 seconds, the DBS will check other switches to 
determine whether to allow or deny the call.
• For all settings (0-3), the system will check the Equal Access Code 
Format switch (FF7 1# 21#...) if a CIC (carrier identification code) is 
dialed to reach a preferred inter-exchange carrier.
• For all settings (0-3), the system will check the international calls 
switches (FF7 1# 1# and FF7 1# 19#) if “01”, “10XXX01”, or 
“10XXXX01” is dialed.
• For settings 2 and 3, the system will not consider TRS settings for the 
trunk.