Honeywell TH1100DV 用户手册

下载
页码 24
PRO TH2000DV/TH1000DV Series
7
69-2800EFS—01
Setup function 
Settings & options (factory default in bold)
  5  Heating cycle rate 
(CPH: cycles/hour) 
TH2110DV, TH1110DV and 
TH1100DV
For gas or oil furnaces of less than 90% efficiency
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficiency
6
For electric furnaces 
[Other cycle rate options: 2 or 4 CPH]
  6  Auxiliary heat 
cycle rate (CPH) 
TH2210DV and TH1210DV
For hot water systems & furnaces of over 90%  
efficiency
1
For steam or gravity systems
5
For gas or oil furnaces of less than 90% efficiency
6
For electric furnaces 
[Other cycle rate options: 2 or 4 CPH]
 9 Compressor 
cycle rate (CPH)
Recommended for most compressors 
[Other cycle rate options: 1, 2, 4, 5, or 6 CPH]
  13  Early Start (TH2110DV 
and TH2210DV)
On **See page 8
0
Off
 14 Temperature 
display
0 Fahrenheit
1
Celsius
 15 Compressor 
protection
Five-minute compressor off time (See page 8)
0
No compressor off time
  20  Clock display (TH2110DV 
and TH2210DV)
12-hour display
1
24-hour display
  25  Lower temperature 
range (TH1100DV only)
Standard range 40°F to 90°F (4.5°C to 32°C)
1
Lower range (for garage mode) 35°F to 90°F  
(1.5°C to 32°C)
  40  Restore program  
schedule to default 
(TH2110DV and 
TH2210DV)
0 Off
1
On - program schedule default settings are listed in the
operating manual
Installer setup
CAUTION: EQUIPMENT DAMAGE HAZARD
Compressor protection is bypassed during testing. To prevent equipment damage, avoid
cycling the compressor quickly.
NOTE: The options below may not be available in all models.