Disassembly
1.
Turn "OFF" both hot and cold water supplies.  Turn
faucet on to relieve pressure and insure complete
shut-off.  Pull handle cap up and off (it snaps into
place).  Remove the handle screw (illustration 1).
2.
Push cartridge stem down and then lift and tilt
handle lever and handle body off.  Leave handle
inside the handle body.
3.
Lift off the retaining ring.
4.
Pry out the retainer clip with a screwdriver (illustra-
tion 2).
Lift off the grooved sleeve.
5.
Use cartridge twisting tool furnished with the
replacement cartridge and rotate cartridge be-
tween
11 and 1 o'clock.
6.
Grasp cartridge stem with pliers.  Pull cartridge out
(illustration 3).
HANDLE
CAP
HANDLE
SCREW
HANDLE
BODY
HANDLE
RETAINING
RING
GROOVED
SLEEVE
ESCUTCHEON
NOTCHED
FLAT
ON STEM
RETAINER
CLIP
CARTRIDGE
SPACER
RETAINER
CLIP
SPACER
MOUNTING
NUT
MODEL 8901
MODEL 4901
HANDLE
HANDLE
SCREW
HANDLE
COVER
ILLUSTRATION 1
FAUCET 
BODY 
RETAINER
CLIP
ILLUSTRATION 2
CARTRIDGE
STEM
ILLUSTRATION 3
CARTRIDGE
EARS
ILLUSTRATION 5
Reassembly
1.
With cartridge stem UP, insert cartridge with ears
aligned front to back (illustration 4).
2.
Push the cartridge down by the ears until the top of
the ears are flush with the top of the body (illustra-
tion 5).
3.
Turn notched flat of cartridge stem toward front of
sink. (Note: for cross piping installations, see in-
structions on back).
4.
Insert  the retainer clip so that the legs straddle the
cartridge ears and slide into the opposite slot in the
body.    Remove clip.  Replace grooved sleeve and
slide clip through the slots into position, this pre-
vents the cartridge from rotating and locks it in the
body (illustration 6).
5.
Replace retaining ring.
6.
Press cartridge stem down.  Holding handle UP,
hook handle ring inside the handle body (illustra-
tion 7) into groove on sleeve.
8.
Swing handle back and forth until it drops down
into place.
9.
Replace handle screw.  Tighten securely.  Push
handle cap down until it snaps into place.
ILLUSTRATION 4
ILLUSTRATION 6
ILLUSTRATION 7
HOLD
UP
EAR
CLIP
HOLD
UP
HOLD
UP
To Eliminate Cross-Piping on Back-To-Back
Installations, or to Correct Reversed Rough-In
Where Hot and Cold Positions are Reversed:
Remove handle cap, handle screw and handle body (see "Disassembly"
instructions).  Turn cartridge stem around so that the notched flat is turned
one half turn or 180
°
.  Re-install handle parts (see "Reassembly").
If handle won't operate properly...you have not hooked handle ring into
sleeve groove.  Hold handle up, hook ring in handle housing into groove