Controlling the AR-200 from an External 
Device (Control Input Connectors)
 
You can use the control input and DC input screw terminals 
(CONT A) and the 25-pin D-sub-type control I/O connector 
(CONT B) on the AR-200’s rear panel to control the AR-200 
from an external device.
This chapter explains how to connect external devices and 
make the settings for the AR-200.
 
What Is No-voltage/Make-
contact?
 
This is contact that makes starting possible simply by 
connecting two lines to the control input connectors and 
shorting their ends. This is a general-use method that lets 
you create start systems easily using only a switch and 
without any need for a power source, enabling easy use for a 
variety of applications.
You can control playback and recording with the AR-200 
using On/Off signals from No-voltage/Make-contact input 
from an external source.
By connecting infrared sensors or switches, relays, and 
timers, or other external starting connectors to the AR-200, 
you can use the unit in an even wider variety of applications.
The AR-200 can help simplify installation operations by 
making the starting-side contact hot and sharing the ground 
as the common connector.
 
For more on the control input specifications, refer to 
 
 
Appendices.
 
Important Note on Using the Control I/O 
Connector
 
The control I/O connector cannot be used to switch the 
power to the AR unit on or off.
 
When making connections to the ports, be careful not to lose 
the removed screws. Place the screws out of the reach of 
small children. If a screw is accidentally swallowed, 
immediately consult a physician.
 
Types of Control Input Playback
 
 
* You cannot use more than one type of playback at the same 
time.
 
Operational Specifications for Control Input 
Playback
 
fig.inp-01
 
Types of Control Input Recording
 
The AR-200 features one type of control input recording, 
 
"Terminal Rec "
 
 
Playback By Card Data
 
Cards Created on the AR-3000, 
AR-2000, or AR-1
 
Playback will use the settings (playback method) recorded in 
the card. For more information, please refer to the owner’s 
manuals for each device.
 
 
Card made on the AR-100/200
 
Playback mode is available Direct Playback(Normal).
Phrases 1 through 9 are assigned to the control I/O connector 
Port Nos. 1 through 9.
 
Direct playback(Normal playback)
 
A phrase is played back when a control signal is input 
directly to the terminal with the number to which the phrase 
is assigned. Up to 9 phrases can be played back.Assign 
Phrases 1 through 9 beforehand to Port Nos. 1 through 9, 
respectively.
This makes it very convenient when you want to specify a 
desired phrase directly using a switch, relay, sensor, or other 
such means.
 
fig.inp-02
Direct Playback
(Reverse Priority)
Interval Playback
Binary Playback
Direct Playback
(Nomal)
When new control signals
are input during playback
of a phrase
When control signals
are input continuously
A phrase in progress is stopped,
and playback of another specified
phrase is begun only when the
control signal being input is of
a higher priority than that of the
phrase currently being played back
Playback stopped, followed by
playback of the specified phrase
Playback stopped, followed by
playback of the specified phrase
Disabled
Repeated
Repeated
Repeated
Repeated
Port No.
Phrase
1
0001
2
0002
3
0003
0004
4
0005
5
9
0009
A Control
Signal
A Control
Signal
A Control
Signal
A Control
Signal
A Control
Signal
A Control
Signal