Roland AR-200 用户手册

下载
页码 72
 
39
Controlling Another Device with the AR-200 (Control Output Connectors)
 
Applications
 
Controlling Another Device 
 
(Control Out)
 
What is the Control Out Signal?/
Connecting Devices
 
The Control Out signal is output for a duration of one second 
from the CONT OUT connector after playback of audio 
phrases, MIDI phrases, pattern phrases, and song phrases.
This signal can be used to start amplifiers and other external 
devices in sync with phrase playback.
You can set the time that is to pass after phrase playback 
before output is made to anything from 0 seconds to 59 
minutes 59 seconds.
Settings are made in phrase units.
The Control Out specifications are no-voltage/make-contact, 
with a make-contact time of 1 second and a contact capacity 
of a maximum of DC 30 V at 3 A.
Port Nos. 15 and 18 have Make-contact during output.
 
Note that if playback of a phrase in progress is cut off, no 
Control Out signal is output.
 
fig.out-03
 
 
 
Output of Control Out Signals In Dual Mono 
Mode (p. 47)
 
Note that Control Out signals are not output in Dual Mono 
Mode (the Control Out settings are not effective).
In such instances, if the Busy Out output settings have been 
made, then the Busy Out signal of the left channel is output 
from the  BUSY OUT connector, and right channel’s Busy 
Out signal is output from the CONT OUT connector.
 
AR-200 Settings
 
* Settings for these parameters cannot be made with the AR-
200. Only phrases set on the AR-3000 are effective. For 
detailed information, please refer to the AR-3000 user’s 
manual.
9
1
18
15
15
18
15
18
Normal
During Output
AR-200_e.book 39 ページ 2003年7月14日 月曜日 午後1時11分